Performing maintenance
84
Instruction manual BFC
15
s
6. Switch the electronic controller
ON
by setting the ON/OFF switch to
position I
.
The display will now show
INTERNAL CHECK
for about 10 seconds, and
will then go to the main menu.
7. Activate "ON mode" by going through the following steps:
-
Press once on the blue arrow ( ) to position the cursor beside
ON
,
then press
.
-
Confirm the selection
START OPERATION
with
.
8. If there is no heat demand, increase Tset
(11.3 "Setting the water
temperature")
. Note the original setting. Draw some hot water off to create
heat demand.
9. Check whether the heating cycle runs correctly
(9.3 "The appliance's
heating cycle")
.
10. If you have adjusted T
set
, return it to the desired value
(11.3 "Setting the
water temperature")
.
11. Remove the plastic cover on the top of the appliance.
12. Check the supply and burner pressure
(3.11 "Checking the supply pressure
and burner pressure")
, and adjust them if necessary.
13. Check that all components of the chimney flue system are properly attached.
14. Check the pressure differential across the orifice plate of the pressure switch
(see the table). If the pressure difference is too low, the heat exchanger must
be cleaned
(15.4.4 "Cleaning the heat exchanger")
.
Pressure switch pressure differential
15. Test the operation of the overflow valve of the protected cold supply setup.
The water should spurt out.
16. Test the overflow operation of the T&P valve. The water should spurt out.
INTERNAL CHECK
MENU
»OFF
^ ON
È WEEK PROGRAM
Appliance
Observed pressure differential across the pressure switch
(Pa)
BFC 80
> 1005
BFC 100
> 1145
n
min
0063
O
I
IMD-0423 R0
Summary of Contents for cyclone BFC - 80
Page 2: ...www aosmithinternational com your installer...
Page 4: ...4 Instruction manual BFC gis...
Page 8: ...Table of contents 8 Instruction manual BFC...
Page 12: ...Introduction 12 Instruction manual BFC 1 gis...
Page 27: ...Instruction manual BFC 27 is Types of appliances IMD 0468 R0 C43 C13 C53 B23 C33...
Page 46: ...Draining 46 Instruction manual BFC 6 gis...
Page 52: ...Status of the appliance 52 Instruction manual BFC 8 gis...
Page 56: ...Shutting down 56 Instruction manual BFC 10 gis...
Page 82: ...Maintenance frequency 82 Instruction manual BFC 14 is...
Page 92: ...Appendices 92 Instruction manual BFC 17 is...
Page 94: ...Instruction manual BFC 94...