Page 21
PROBLEM
Engine is running,
but no AC output is
available.
1. AC Circuit breaker is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
5. GFCI outlet is open (if equipped)
1. Check AC load and reset circuit breaker.
2. Contact customer service or authorized service center.
3. Check and repair.
4. Connect another device that is in good condition.
5. Correct ground fault and press reset button on GFCI outlet.
Engine runs well at
no-load, but "bogs
down" when loads is
connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
5. Clogged or dirty fuel filter.
6. Connected device is bad.
1. Disconnect shorted electrical load.
2. Contact customer service or authorized service center.
3. Reduce load.
4. Contact customer service or authorized service center.
5. Clean or replace fuel filter.
6. Connect another device that is in good condition.
Engine will not start;
starts and runs rough
or shuts down when
running.
1. Engine switch set to OFF (O) position.
2. Fuel valve is in OFF (O) position.
3. Low oil level.
4. Dirty air filter.
5. Out of fuel.
6. Stale fuel.
7. Spark plug wire not connected to spark plug.
8. Bad spark plug.
9. Water in fuel.
10. Flooded.
11. Excessively rich fuel mixture.
12. Intake valve stuck open or closed.
13. Engine has lost compression.
14. Clogged or dirty fuel filter.
15. Clogged or dirty spark arrester screen.
1. Set engine switch to ON (l) position.
2. Move fuel valve to ON (l) position.
3. Fill crankcase to proper level or place generator on
level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Drain fuel tank and carburetor; fill with fresh fuel.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain gas tank and carburetor; fill with fresh fuel.
10. Wait 5 minutes and re-crank engine.
11. Contact customer service or authorized service center.
12. Contact customer service or authorized service center.
13. Contact customer service or authorized service center.
14. Replace fuel filter.
17. Clean or replace spark arrester screen.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
4. Clogged or dirty spark arrester screen.
5. Engine needs to be serviced.
6. Bad fuel.
1. Reduce load.
2. Replace air filter.
3. Clean or replace fuel filter.
4. Clean or replace spark arrester screen.
5. Contact customer service or authorized service center .
6. Drain gas tank and carburetor; fill with fresh fuel.
Engine“hunts”or falters. 1. Carburetor is running too rich or too lean.
2. Clogged or dirty fuel filter.
3. Choke is opened too soon.
1. Contact customer service or authorized service center .
2. Replace fuel filter.
3. Set choke to halfway position until engine runs smootly.
Engine shuts down
when running.
1. Out of fuel.
2. Dirty air cleaner.
3. Low oil level.
1. Fill fuel tank.
2. Clean or replace air cleaner.
3. Fill crankcase to proper level or place generator on
level surface.
POSSIBLE CAUSE
SOLUTION
TROUBLE SHOOTING
Summary of Contents for AP5000
Page 24: ...Page 22 PARTS DIAGRAM PARTS DIAGRAM AND PARTS LIST AP5000 ...
Page 30: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 32: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 60: ...Página 26 DIAGRAMA DE PIEZAS DIAGRAMA DE PIEZAS Y LISTA DE PIEZAS AP5000 ...
Page 66: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 68: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 94: ...Page 24 DIAGRAMME DES PIÈCES SCHÉMA DES PIÈCES ET LISTE DES PIÈCES AP5000 ...
Page 100: ......
Page 101: ......
Page 102: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 104: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...