background image

EN

EN

12

13

Installation and instruction manual

1.  General description

Elios4you Smart is a monitoring device used with photovoltaic sys-
tems for managing self-consumption of three-phase consumers rat-
ed 15 kW, 50 kW or 100 kW (depending on the model) 
Users can configure and monitor the production of their photovoltaic 
system simply and intuitively by way of the “Elios4you” App.

Contents of the pack

 

9

1 x Elios4you Pro

 

9

1 x external antenna

 

9

6 x split core CT (current transformer)

Products compatible with Elios4you Pro

 

9

Pro Smart

 

9

Power Reducer

 

9

4-cloud (web service)

2.  Safety warnings

All hardware connections must be made by a person who is suitably 
qualified and aware of the risks associated with installation, observ-
ing the requisite standards of safety, and with the equipment isolated 
from the power supply. 
The user accepts all responsibilities and risks connected with the steps of installing, configuring and using products to the end of obtaining 
the benefits and advantages they afford. The liability of the Astrel Group in respect of its products is regulated by the Astrel Group General 
Conditions of Sale (published on the company’s website www.astrelgroup.com).
Do not disassemble, open up or attempt to repair the product. Opening up a sealed component has the effect of invalidating the warranty.

3.  Installation

Prior to installation

ID CODE: 00000

Register on: www.4-cloud.org

and pair your device

with USER: 

XXXXXXXX

Before installing the Elios4you device, remove the label illustrated alongside, which indicates the 
USER code. Keep the label: it will be used for configuring other mobile devices with Elios4you and 
possibly accessing the www.4-cloud.org portal (accessory service available in the case of configura-
tions with router/AP). 
When a device is configured via Router/AP, the pertinent data can be seen on the portal about one 
hour after the configuration.

Warnings for installation

Parts indicated as carrying dangerous voltage, live inputs, current probes and the relay output, must be protected against the risk of causing 
electric shock using connections with double or reinforced insulation, connecting cables included.
The instrument must be installed in an electrical cabinet affording the appropriate protection against access to dangerous live components, as well as 
guaranteeing the disconnection of live parts generally, if necessary.

The disconnect breaker is to be provided by the installer and must meet certain requirements, namely:

 

9

it must be located in an easily accessible place

 

9

it must be clearly identified as a component used to disconnect the device.

The installer must provide overload protection for the relay, if utilized.
If the device is used in a manner not specified by the manufacturer, the effectiveness of the protection provided could be jeopardized.
Any repairs on the appliance must be entrusted only to persons authorized by the manufacturer.

Fixing and first power-up

1) 

Fix the device to a DIN rail, making the connections as in the installation diagram (Fig. 2).  

Caution:

 if the CT cable needs to be extended, it is advisable to use a 2x0.75 mm

2

 screened cable of length not exceeding 20 m.

2) 

Having installed and powered up the device, download the free “Elios4you” App for tablet or smartphone from App Store or Google 
Play Store, and proceed to install it

3) 

Launch the “Elios4you” App and follow the steps of the guided configuration procedure, screen by screen. For more information, go 
to www.4-noks.com/tutorial.

4) 

Set the correct parameters of the photovoltaic system and the household electrical consumer by way of the App: Menu 

 

 

“System Parameters” 

 

 select “Energy Management” and enter the preferred values. 

 On completing the operation, tap OK

5) 

For more information, go to www.4-noks.com/tutorial

Check installation

6) 

Check on this page that all items of data are correct: 
•  Tap the “Home” icon 

 to go back to the “System activity” page

•  Make certain that the value of the power output — “Production” 

 — corresponds to the reading of the inverter

•  Check whether or not the “Consumption” value corresponds to instantaneous usage by the monitored consumer

CAUTION:

 when Elios4you is configured for access to the internet (via Router/AP), the data log will also be sent to the 4-cloud portal. Connect 

to the cloud site www.4-cloud.org and follow the instructions for registration. Adopt the USER code indicated on the label for pairing the device.

4.  Response of Leds (table 1)

Led

Colour

Meaning

Red

Production of photovoltaic energy. Blink frequency proportional to the amount of energy generated by 
the photovoltaic system

Red

Blink frequency proportional to the amount of energy exchanged with the grid

Green

Power supply

Green

Wi-Fi active

Red

No connection between Elios4you and tablet or smartphone

Green

Not used

CAUTION: 

ensure that there are no other consumers connected between the CTs and the relative meters, or branches, otherwise the meas-

urements will not be correct.

110 mm

105 mm

60 mm

45 mm

Fig. 1A: Remove the cover on the right hand part of the device

Fig. 1B

How to access the button

Button

Summary of Contents for ELIOS4YOU Pro

Page 1: ...Installation and instruction manual 4 noks Elios4you Pro IT EN FR DE...

Page 2: ...ption 12 Contents of the pack 12 Products compatible with Elios4you Pro 12 2 Safety warnings 12 3 Installation 12 Prior to installation 12 Warnings for installation 12 Fixing and first power up 12 Che...

Page 3: ...solution des probl mes 21 9 Conformit 21 10 S curit et limination 21 11 Sch ma d installation fig 3 22 Installations und Bedienungsanleitung 24 1 Allgemeine Beschreibung 24 Verpackungsinhalt 24 Mit El...

Page 4: ...mente raggiungibile 9 9 deve essere chiaramente indicato come componente per la disconnessione dell apparecchiatura L installatore deve provvedere alla protezione da sovraccarico del rel se utilizzato...

Page 5: ...bile che i TA siano stati posizionati in una diramazione dell impianto 9 9 Assicurarsi che uno o pi TA non riportino internamente segni evidenti di rotture 3 Il consumo rilevato segue l andamento dell...

Page 6: ...generico opzionale max 10 A 240 Vac Ingresso allarme 1 COMUNE allarme 1 Ingresso allarme 2 COMUNE allarme 2 Non cablare Non cablare Interruttore generale TA produzione etichetta bianca Punto verde e d...

Page 7: ...he installer and must meet certain requirements namely 9 9 it must be located in an easily accessible place 9 9 it must be clearly identified as a component used to disconnect the device The installer...

Page 8: ...the grid CTs yellow label about face so that the green dot or the arrow on the inside of the CTs is positioned on the opposite side to that currently in use 9 Conformity All models comply with Directi...

Page 9: ...3 N L1L2 L3 N L1 L2 L3 N Generic load optional 10 A max 240 Vac Production CT white label Green dot and direction of arrow K L toward main switch Relay contact N O X X X X X X X X IN 10 V GND Ctrl Ter...

Page 10: ...us les branchements mat riels doivent tre effectu s par du per sonnel qualifi et conscient des risques d une installation en tenant compte des normes minimales de s curit et en l absence de tension L...

Page 11: ...tr s peu 9 9 Contr lez que les TI de r seau tiquette jaune couvrent l ensemble des lignes la sortie du compteur avant leur ramification sur l installation lectrique 9 9 Faites pivoter les TI d change...

Page 12: ...L1 L2 L3 N Charge g n rique en option max 10 A 240 Vac TI production tiquette blanche Point vert et direction de la fl che K L vers l interrupteur g n ral Contact relais N O X X X X X X X X IN 10 V G...

Page 13: ...hl sse sind durch Fachpersonal ohne an liegende Spannung unter Ber cksichtigung der Installationsrisiken sowie der Mindestsicherheitsanforderungen auszuf hren F r die Erreichung der f r die einzelnen...

Page 14: ...gewissern Sie sich dass die Netz Stromwandler gelbes Etikett auf den Ausgangsleitungen des Z hlers vor einer Abzweigung der elektrischen Anlage gelegt sind 9 9 Die Austausch Stromwandler gelbes Etiket...

Page 15: ...max 10 A 240 Vac TA Erzeugung wei es Etikett Gr ner Punkt und Richtung des Pfeils K L zum Hauptschalter Relaiskontakt Schlie er X X X X X X X X IN 10 V GND Ctrl Klemmen N L1 L2 L3 Mindestquerschnitt...

Page 16: ...30 Note Notes Notes Anmerkungen...

Page 17: ...4 NOKS is a brand of ASTREL GROUP ASTREL GROUP SRL Via Isonzo 21 E 34070 Mossa GO Italy www astrelgroup com www 4 noks com 05T408110R4 0 Elios4you Pro Instruction manual IT EN FR DE 2018 06 29...

Reviews: