User manual
54
Chapter 6 other function configure
6.1 DIP switch
IES618-4D series have 4 DIP switch. Can default factory through DIP 3.
DIP switch
ON function
1
Hold
2
Factory default
3
Hold
4
Hold
6.1.1 Factory default
Put the DIP switch 3 to ON, Power ON again, the default factory finished. After default factory, must put
the DIP switch to OFF, otherwise, will default factory again when power ON next time.
:
Except DIP switch 3 need to put ON when default factory. Other DIP switches must always in OFF status, otherwise, the
device may work unusual