MDM_OVER_TEMP
event.warning.hw
The measured temperature is higher than the
warning threshold, but not high enough to cross
fault threshold.
None required.
MDM_
POWERMEASURE_
CLIPPED
event.warning. radio
An error is detected in the power reading
process.
None required.
MDM_
PREDISTORTION_
DATA_MISSING
event.warning.hw
Unable to find valid predistortion calibration data
from the reader flash.
None required.
MDM_RC_NO_
AVAILABLE_
FREQUENCIES
event.warning. radio
The modem is unable to find valid frequencies.
None required.
MDM_REFLECTED_
POWER
event.warning.
antenna
An antenna's return loss is lower than the
warning threshold, but not low enough to cross
the fault threshold.
None required.
MODULE_NOT_
INITIALIZED
event.warning.sw
Indicates a failure in module initialization.
None required.
NULL_POINTER
event.warning.sw
Indicates a failure in the pointer.
None required.
READER_RESET_FP
_SWITCH_FACTORY
_ SET_ERROR
event.warning.sw
Error detected during reset of profile to factory
default when pressing the hardware reset
switch.
None required.
READER_RESET_FP
_SWITCH_NETWOR
K_SET_ERROR
event.warning.sw
Error detected during reset of network to factory
setting when pressing the hardware reset switch.
None required.
READER_RESET_FP
_SWITCH_SERIAL_
CONSOLE_SET_
ERROR
event.warning.sw
Error detected during reset of serial interface to
CLI when pressing the hardware reset switch.
None required.
READER_RESET_FP
_SWITCH_SERIAL_
RAWMODE_SET_
ERROR
event.warning.sw
Error detected during reset of serial interface
raw mode to FALSE when pressing the hardware
reset switch.
None required.
READER_RESET_FP
_SWITCH_SERIAL_
SET_ERROR
event.warning.sw
Error detected during reset of serial interface
parameters when pressing the hardware reset
switch.
None required.
SPARSE_ARRAY_
NULL
event.warning.sw
Indicates a non-existent sparse array.
None required.
SYMBOL_TABLE_
DEFAULT_INVALID
event.warning.sw
Default value is invalid for the symbol.
None required.
SYMBOL_TABLE_
FAILED_TO_
RESTORE
event.warning.
configuration
Indicates a failure in restoring the
configurations.
None required.
SYMBOL_TABLE_
FAILED_TO_SAVE
event.warning.
configuration
Indicates a failure to save the configurations.
None required.