Major
Major
Major
Major Error
Error
Error
Error
Event
Event
Event
Event
Description
Description
Description
Description
Corrective Action
Corrective Action
Corrective Action
Corrective Action
MDM_ICM_ERROR
event.error.
communication
An inter-core message
response on the modem
has an error.
Contact 3M support.
MDM_ICM_TIMEOUT
event.error.
communication
An inter-core message
response on the modem
has timed out.
Contact 3M support.
MDM_INVALID_RX_
COMB_LENGTH
event.error.sw
Invalid receiver filter length
is detected.
Contact 3M support.
MDM_INVALID_RX_
Q_CHANNEL_COEFS
event.error.sw
Invalid receiver filter
coefficient is detected.
Contact 3M support.
MDM_IPRC_CRC_
ERROR
event.error.
communication
Modem has received
communication from main
processor which fails CRC
check. May see at boot up,
since processors may come
up (and start sending
messages) at slightly
different times.
Contact 3M support.
MDM_IPRC_
OVERFLOW
event.error.
communication
Modem communication
buffer that receives data
from the main processor
has overflowed and data
has been lost.
Contact 3M support.
MDM_IPRC_TRY_
AGAIN
event.error.
communication
Modem communication
buffer that receives data
from the main processor
has no full message yet.
Contact 3M support.
MDM_L1_TX_PACKET
_TIMEOUT
event.error.
communication
Lowest level physical layer
transmit process timed out.
Contact 3M support.
MDM_LOW_VOLTAGE
_FAULT
event.error.
environmental
Low voltage on digital
portion of modem.
Verify correct operational voltage is
being supplied to reader. Verify power
supply voltages meet 3M specifications.
If condition persists, contact 3M support.
MDM_MINIMUM_
GAIN_LIMIT
event.error.sw
Receiver gain limit is
exceeded.
Contact 3M support.
MDM_PHY_ENCODER
_TIMEOUT
event.error.hw
The modem transmitter has
failed to complete a
transmission.
If condition persists, contact 3M support.
MDM_PPI_DEVICE_
FAILURE
event.error.hw
The PPI interface has
generated an error.
Contact 3M support.
MDM_RESET_
COMPLETE_MDM_
DOWN
event.error.hw
The main processor has
reset the modem, but has
been unable to
communicate with it.
Perform reader reboot. If condition
persists, contact 3M support.