1
2
3
4
5
6
7
8
8
8
8
9
Configuring Digital I/Os
Configuring Digital I/Os
Configuring Digital I/Os
Configuring Digital I/Os
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
User’s Guide
User’s Guide
User’s Guide
User’s Guide
85
85
85
85
8.4.4.
signal_read
signal_read
signal_read
signal_read_crc_error.py
_crc_error.py
_crc_error.py
_crc_error.py
This routine will turn on a digital output if a tag read CRC error is detected. The
output pin number can be specified on the command line. If not specified,
output pin 1 is used. The output pin will remain high for n ms, where n is either
the default of 1000 ms or the value supplied on the command line. Minimum
value for n is 10 ms.
Inputs:
<pin> – (optional) Output pin number (1–4). Default is output 1.
<time> – (optional) Time, in ms, to keep the output high. Default is
1000 ms.
<logic level> – (optional) Logic level for digital out On. 0 or 1.
Default is 1 (On).
Examples:
signal_read_crc_error.py
Turns on output 1 (logic level 1=on),
for 1000 ms on tag read CRC error.
signal_read_crc_error.py 2
Turns on output 2 (logic level 1=on),
for 1000 ms on tag read CRC error.
signal_read_crc_error.py 1 5000
Turns on output 1 (logic level
1=on), for 5000 ms on tag read
CRC error.
signal_read_crc_error.py 1 500
Turns on output 1 (logic level
1=on) for 500 ms on tag read CRC
error.
signal_read_crc_error.py 1 800 0
Turns on output 1 (logic level
0=on), for 800 ms on tag CRC
error.
8.4.5.
rf_mon.py
rf_mon.py
rf_mon.py
rf_mon.py
This routine will monitor the state of the transmitter. If the transmitter is on, it
sets the appropriate output pin high. If low, it sets the output pin low.
Inputs: <pin> – (optional) Output pin number (1–4). Default is output 1.
<logic level> – (optional) Logic level for digital out On. 0 or 1.
Default is 1 (On).
Examples:
rf_mon.py
Monitors RF status, set/clear output 1 on change, logic
level 0 for on
rf_mon.py 1
Monitors RF status, set/clear output 1 on change, logic
level 0 for on
rf_mon.py 2
Monitors RF status, set/clear output 2 on change, logic
level 0 for on
rf_mon.py 3 0
Monitors RF status, set/clear output 3 on change, logic
level 1 for on
Summary of Contents for 6204
Page 1: ......