Pag. 8
DUALNET-6 MANUAL
ENGLISH
Brief description of keypad commands:
(*) Note: the control of the hardwire zones (from 1 to 14) is active only if the program is set in “Zone Ready”
and “YES” is selected. (See page 22). In any case the zones that are triggered when the panel is armed, will
be automatically by-passed but will become active if the zone is normalized. Example: if i have a door
open and i force arm the panel, this zone will be by-passed. If I then close the door without disarming the
panel this zone will again become active.
Command
Function
Note
[End user pa[ 1 ]
To disarm the control panel
[End user password ]+[ 2 ]
To arm the control panel in “Day mode”
If you select the zone option as “Yes”, the panel
will ask if you wish to Arm with a zone triggered
and if you confirm, this Zone will be automati-
cally by-pass until the panel is Disarmed and
again Armed.(*)
[End user pa[ 3 ]
To arm the control panel in “Night mode”
If you select the option “Ready to Arm” the
panel will request a confirmation if a zone is
triggered. If you select to force arm, this zone
will be automatically by-passed until it has been
normalized (*)
[End user pa[ 4 ]
Forced “Day” arming
All zones triggered are automatically by-passed.
If normalized, the will become active again. (*)
[End user password ]+[ 5 ]
Alarm trigger test
A 3 second trigger will take place and transmitted
to the CMS by means of Contact ID, If this has
not been programmed, a message will be sent to
the memorized tel. numbers followed also by a
voice messaged if recorded.
[End user pa[ 6 ]+ [Zone
XX]
By-pass Zone “XX” With control panel
armed.
Once the control panel is disarmed, the zone
“XX” will return to its original status.
[End user pa[ 7 ]
Forced “Night” arming
All zones triggered are automatically by-passed.
If normalized, the will become active again. (*)
[End user pa[ 9 ]
With control panel disarmed, you may activate
or deactivate the acoustic keypad sounder. On
keypad display you see (Area cue tone)
This function is active only if a zone is
programmed for this function (see “Set Smart
Zone” page 21 and 22).
[ #]+ [Installer password]
To program the control panel.
The installer must use this password to enter into
programming mode. After 3 negative attempts
the control panel will return to the Disarmed
mode.
Command
Function
Note
If this key is pressed, it will indicate the Zones
in which the installed sensors are triggered.
If this Key is press for 2 seconds the control
panel will generate a HOLD-UP Alarm trigger.
If this Key is pressed for 2 seconds the control
panel will generate a FIRE Alarm trigger.
If this key is pressed for 2 seconds the control
panel will generate an EMERGENCY alarm
trigger.
o
With control panel Armed, if these Keys are
press the GSM signal strength will be seen.
During programming, these keys are used to
navigate with-in the program menu.