DUALNET-6 MANUAL
ENGLISH
In order that this function be active you must set the display so that it will show 00010 to 99999
minutes, if the display shows this test is not in function. (from 00001 to 00009 is not accepted.)
At the end press the key to return to the preceding menu or the key to go to the next
menu.
Note: With the above setting in function, the Dualnet-6 will send a full report of its status in a given
time period as shown on the display. This includes (Mains 230Vac, Low battery, Zone failures,
Telephone line failures, etc.) In the case of panel failure or alarm trigger, the control panel, through
the on-board telephone diallers, will send in real time, all the events taking place .
08. TELEPHONE LINE TAMPER CONTROL
Enter the programming menu and go to the window
“PSTN Failure”
Press the key on the display will appear:
With the keys or select “ YES” or “NO” and confirm with
Automatically you will return to the preceding menu.
Note: By selecting “YES” on “Phone Anti-cut”, if the control panel is not in programming mode and
the PSTN telephone line is not present, on the display will appear “Phone cut” and two beeps will
emitted every 7 seconds by the keypad.
E
PSTN Failure
YES NO
E
“Automatic test time”
indicates time
that goes by between two messages
of control panel working correctly to
the CMS
Auto Test Time
00000
#
E
If this number is set to
00000
this indicates that this function is not
active
PS
CMS Options
TN Failure