Pag. 7
DUALNET—6 INSTRUCTION MANUAL
ENGLISH
Brief description of the panel status on keypad display:
While panel is not armed press or
to have the GSM status information; After 20 seconds
the keypad will return to normal status.
NOTE: In the case you see, on keypad, “NO SIM CARD” even if the SIM card has been put in,
remove all power to the panel (230vac and 12vdc), Check that the SIM card has been correctly
installed and power up the panel again.
The following info will be displayed on the keypad once there is an event:
(*) This is active only if the setting is (Y) in the CMS management menu. (see pag.17)
Information seen on display
Meaning of information seen
Action to take
GSM Signal Strength:
XX :YY
No SIM Card: XX:YY
GSM signal level XX = 8 and above is
“OK” is seen. If XX = 7 and below “NO”
is seen.
XX = signal strength from 8 to 10
YY = “OK” or “NO”
If the GSM signal is below 8, attempt to reposi-
tion the GSM antenna.
Verify if the SIM card is correctly inserted.
Phone Cut (*)
PSTN line fault
Check PSTN telephone line. If connected or if
faulty.
System Armed
XX YYYYY
Zone triggered: XX zone number
YYYY zone description
Control panel triggered: verify zone triggered
Communicating 00 YYYY (*)
Send message to memorized telephone
numbers using (SMS or CONTACT ID)
Armed
Disarmed
Low battery
Battery OK
Mains failure 230Vac.
Mains Okay
Manual Test
Auto Test
System control
Send SMS Immediate
Send SMS Immediate
Send SMS after 5 seconds
Send SMS after 5 seconds
Send SMS after about 10 minutes
Send SMS after 3 seconds
Send SMS after 3 seconds
Send SMS after 1 minute (see settings page 18)
Not ready
XX YYYYY
Zone not ready XX = Zone: YYYY Sensor
Description.
Power Failure (*)
Mains 230V ac. Not present.
Check incoming mains service. If okay, check
1Amp. Delay action fuse in control panel. If
okay, check power supply input and output.
(see page 4 and 5 point 10)
Low battery(*)
Normal battery output 13.8 V. If it goes
below 10 V, Display = Low battery.
Check if mains 230Vac. Is present.
Test of battery is efficient.
Check power supply output voltage if 13.8Vdc.
Normal battery life 3 to 4 years.
YYYY. MM. DD.
HH:mm:XX:Day
On the keypad display you will see:
YYYY= year, MM=month, DD=day
Followed buy:
HH= hour (format 12h), mm= minutes
XX=AM or PM, Day= day of week
ARM :YYYYYY
HH:mm:XX:Day
Panel ARMED in YYYYYY= Day or
Night HH = hour : MM = minutes XX =
AM or PM : Day =DAY of week
When armed the display will show DAY or
NIGHT