Pag. 4
DUALNET-6 MANUAL
ENGLISH
Control Panel Description:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
Z7 GND Z8 Z9 GND Z10 Z11 GND Z12 Z13 GND Z14
2
3
1
4
6
7
8
9
5
Fig.1
EXT. PULSE NO +12V RX TX GND MIC2N MIC2P BEEP
AUX Z1 GND Z2 Z3 GND Z4 Z5 GND Z6
RELAY SIREN ON NIGHT
POWER 12VOLT
TAMPER
KEY ALARM
ELETT. AUTO. GND LED KEY PAD
11
230 Vca/
Vac
GND
Fusibile
Fuse
ATTENZIONE
Rischio di scarica elettrica
CAUTION
Risk of electric shock
10
12
Terminal Description of function
1-2
D.C. 14 volt regulated power input through 1.8amp. on-board switching power supply.
3-4
D.C. 12 volt auxiliary power for all sensor that require 12 Vdc. Power current max 2A.
5 to 13
Number 6 programmable
double balance
line hardwire zones. All wired zone are By-passed (see pag.19)
14
EXT TAMPER: Balanced line input tamper terminal with end of line resistor of 2,2 K
Ω
.
15
PULSE KEY input. This is the remote input to Arm/Disarm the control panel. 1st pulse panel Armed,
2nd pulse panel Disarmed.
16
Normally open alarm relay. When panel is in stand-by this relay is Normally Open. When panel is trig-
gered a negative command will be present. Maximum drain 2Amp.
17
Output for electronic siren. This output must be connect to a common ground. No voltage present when
panel is in stand-by. When the panel is triggered to 13.8 Vdc. will be present for the alarm duration time.
Maximum drain 2 amp.
18
This output must be connected to a common ground. It is used to recharge the battery for sirens with back
-up batteries. With panel in Stand-by 13.8Vdc. is present with panel triggered 13.8 Vdc. will disappear
for the alarm time and the outdoor siren will trigger.
19
Common ground Terminal for the above 17 & 18.
20
Led “ON” This output must be used hardwired with a common ground to create a remote LED indica-
tion to signal Panel Armed or Disarmed.
21
Led “NIGHT” This output must be used with a common ground to create a remote LED indication to
signal panel Armed/Disarmed status in night mode.
22
12 V dc. Power to Touch Screen Keypad
DN-6KP
23-24
RX / TX transmission data from Keypad to mother board.
25
Keypad ground connection.
26-27
MIC2N and MIC2P Microphone connections to keypad.
28
BEEPER Keypad buzzer connection.