3DGence Material Management System | version 1 | 03.2022
1.6.
Place of installation
Information on where to install the device:
•
the device should operate at temperatures between 10 °C and 28 °C and relative humidity between 30% and 60% without
condensation,
•
the device should be stored at temperatures between -
20 °C and 54 °C and relative humidity between 10% and 85%
without condensation,
•
in order to prevent spreading of vibrations and noise, the device should be placed on a stable surface with a load capacity
sufficient for the weight of the device, e.g.: concrete floor; it is not recommended to install the device on e.g.: metal sheet,
chipboard, wooden planking, etc.,
•
the level of emission of non-ionising electromagnetic radiation generated by the device is within the limits specified by the
standards: for the 3DGence Material Management System device: EN 61326-1, EN 55011, and for the built-in wireless
communication device: EN 300 330, EN 55032, EN 301 489-1/-3,
•
sufficient free space must be available within the MMS based on the external dimensions of the device; in addition, all
sides of the printer must be accessible for, among other things, loading of the materials or maintenance work in accordance
with the manufacturer's recommendations,
•
the operator may occupy a position at the front of the device; it is not recommended to occupy a position at the back of
the device due to the noise and/or heat generated,
•
before starting the MMS for the first time, the manufacturer recommends that the device is left for minimum 2 hours
before being connected to a power source in order to stabilise the temperature.
•
the place of installation of the device should be adapted to the connection specifications,
•
the device is not suitable for use in dusty environments,
•
the room in which the device is installed must be ventilated appropriately for its size,
•
the device must be placed on a firm and stable surface, suitable for its weight (Table 1),
•
the device must not be exposed to direct sunlight,
•
the device should stand away from other heat sources; direct, prolonged exposure to sunlight should be avoided,
•
the use of an external UPS is recommended so that the device will not interrupt its operating cycle in the event of a
temporary power failure,
•
the height of the installation site should not exceed 2000 m above sea level.
850mm
Fig. 2 Maximum size of the 3-chamber MMS (width)