q u i c k s t a r t g u i d e
r d m i n s t a l l a t i o n a n d r e m o v a l
31
Partially Full Containers
Before starting this procedure, make sure that the container slot is empty. If a container is present,
refer to the previous section, “Removing Empty Resin Containers,” before continuing. While
wearing protective clothing, disposable nitrile gloves, and goggles, perform the following steps:
1 Open the resin refill door until it is completely inverted.
2 Release the inner door latch and open the container holder door.
3 Place a resin container into the container slot and remove the container lid and the induction
seal.
4 Close the container holder cover until the inner cover latch has been properly locked.
5 Lift the resin refill door until the vent cap faces up and the refill door is nearly closed.
6 Remove the vent cap and place it on the cap retainer for storage.
7 Using the puncture tool, place a small vent hole in the center of the vent spout.
8 When the vent hole has been made, return the puncture tool to the holding clips.
9 Close the resin container door firmly until it latches securely.
Caution!
If the O-ring is not seated correctly inside the neck of the resin container, or the
door is not properly latched, a resin spill is likely.