r d m r e m o v a l
37
2 Sit the platform on two L-shaped guides in the rear of the RDM.
3 Push the platform against the front platform guides.
4 The notches in the platform need to engage into the front platform guides
5 Go to the Control Panel, select a part, and start a build.
6 When correctly installed and started, the elevator main stage moves to the Build Start position.
Platform Release
After the build is complete, select “drain platform.” This function raises the elevator motion stage
to the top and the locking mechanism disengages. The user can then reach in, move the platform
backward, release the locking tab, and then slide the platform back and remove it.