q u i c k s t a r t g u i d e
l a s e r s
53
The controller and power supply is in 19 in. rack packaging. It provides all control and
power interconnect with the laser head and monitors cooling system performance.
xx: picture?
Laser Head
The output wavelength for the laser head is 354.7nm. The UV power is 1.5W. Picture?
Laser Cooling System
The Viper Pro system uses a self-contained, or closed, coolant delivery system that mechanically
interfaces to the laser head heat sources. All liquid lines use dry-dry quick-disconnect couplings.
A 3D Systems Customer Support Engineer should perform any other servicing of the chiller or
heat exchanger.
Beam Profilers
The SLA system contains two beam profilers that are located near the front and rear of the resin
delivery module. The profilers determine the actual X and Y axis location of the laser beam
relative to the build zone. The profilers then feed this X and Y axis location information to the
control computer where real-time accuracy adjustments can be made to account for changes that
may occur layer to layer.