3D Systems, Inc.
65
Chiller Maintenance
Routine inspection and, if necessary, maintenance for the HRS024 SMC chiller is recommended to be completed on a weekly basis .
This will include replacing the chiller air filter, replacing the chiller fluids, replacing the chiller fluid filter and inspection of all coolant
lines . For detailed instructions on the chiller, refer to the OEM
Operation and Installation Manual:
http://content2 .smcetech .com/pdf/
manuals/HRX-OM-M090-G .pdf
Replacement Parts
Part Number
Description
132564-00
Pentek CW-F Polypropylene Wound Filter (Scott Equipment #155186-43)
132576-00
SMC Filter Element AF/AW30 (Scott Equipment #AF30P-060S)
9208-30021
Water Distilled 1 Gal McM 3190K901
110362-00
Opti-Shield PN “400113”
http://www .optishield .net/
(1 quart)
Chiller Fluid Replacement
Clean the tank, circulating fluid circuit, and change the circulating fluid
in the tank if any problems are found during a regular check .
It is necessary to change the fluid once every 3 months in case
evaporation of the fluid causes concentration of impurities.
The chiller has a fluid capacity of 5 liters (1.3 gallons). It requires a
mixture of one pint of
OptiShield
(p/n 110362-00) to one gallon of
distilled water
(p/n 9208-30021) .
Refer to the OEM documentation for detailed instructions .
Tank Lid
Circulating
Fluid Fill
Liquid Level
Air vent filter replacement
Drain filter replacement
Fluid replacement
Cleaning the Chiller Air Vent and Changing the Air Vent
Filter
If the fins of the air-condenser become clogged with dust or debris,
heat radiation performance reduces . This results in the reduction of
cooling performance, and may stop the operation because the safety
device is triggered .
Shut off the power supply of the product when performing cleaning, maintenance or inspection
to avoid electric shock, injury or burn, etc .
Use a long bristled brush or air gun to clean the condenser to prevent the fins from being
deformed or damaged .
To replace the filter, remove the filter panel and replace with “SMC Filter Element AF/AW30
(Scott Equipment #AF30P-060S)” (p/n 132576-00) .
Refer to the OEM documentation for detailed instructions .
Drain Filter Replacement
When the chiller is free of fluids, open the drain
filter housing at the rear of the chiller and uninstall/
reinstall a Pentek CW-F Polypropylene Wound Filter
(Scott Equipment #155186-43) .