3D Systems, Inc.
58
CAUTION: Before beginning any of the procedures in this section, make sure that the printer has cooled down
adequately to prevent burn hazards .
The following figure illustrates the bottom surface of the print chamber, as if you were looking straight down from the ceiling of the print
chamber .
NOTE: Refer to the appropriate Material Guide for special cleaning instructions for specific materials.
Overflow opening
Part return piston
Roller
Part piston / material bed
Interface ring
To Clean the Print Chamber
1 . Close outer print chamber door . Close and latch the inner print chamber door .
2 . Put the
Sinter
application in
Manual Operations
mode .
3 . If necessary, exit
mode . Then select the
Man Ops
button to access the manual operations screen .
4 . Using the
Roller
screen, move the roller to the center position .
5 . Open the outer print chamber door . Unlatch and open the inner print chamber door .
6 . * Vacuum and brush the material from the seal around the inside of the print chamber door . Use a non-ignition vacuum cleaner .
7 . * Clean the door with the tack cloth and vacuum the door and the window . If necessary, clean the window with ethanol or glass
cleaner .
NOTE: Use only soft cloths or paper towels and non-abrasive cleaners on the inside of the print chamber window
to avoid damaging the coating that prevents the laser beam from escaping during the print process .
8 . There are pull pins on the front of the heaters which will release them .
9 . Vacuum and wipe off the entire roller assembly .
10 . Clean the roller . See the section,
“Cleaning the Roller Assembly” on page 59
.
11 . * Wipe the print chamber walls with a tack cloth .
12 .
Clean under the roller. To see the overflow on left, the powder chute must be lifted manually.
a . Close the inner and outer print chamber doors .
b . The roller should be in the center . If not, press the green
System On
button to engage the roller contactor .
c . Use the
Roller
button to move the roller .
d . Unlatch and open the print chamber doors .
e .
Brush material in the area that had been covered by the roller into the overflow, then clean the area with a non-ignition
•
Lab-grade acetone and lab-grade ethanol
•