Installation Procedures
15
Installation
Procedures
This section provides detailed instructions for completing the steps in the
installation procedure illustrated earlier in Figure 3.
Step 1 (Optional): Install
the Optional Modules in
the Unit
This section tells you how to install the optional modules in the PathBuilder
S330/S310 chassis.
In order to execute the release 2.04 software with the new Ethernet 10/100 and
four-port IMA modules, the PathBuilder S330/S310 switch must be equippped
witha specific motherboard revision. For a list of the required part/revision number
combinations and instructions for how to check the motherboard part and
revision numbers, see “Verifying Hardware Requirements”in Chapter 4.
The PathBuilder S330/S310 swtich supports five optional modules:
■
CBR module
— A board consisting of one V.35/RS-366/RS-449/RS-530/X.21
interface and three T1-DSX or E1 interfaces (one T1-DSX or E1 interface for the
PathBuilder S310 switch). It services traffic generated by your existing PBXs,
channels, T1/E1 multiplexers, CSU/DSUs, and video conferencing devices.
Install the CBR module in slot 7. Figure 6 shows the CBR module connections.
Figure 6
CBR Module Connections
PBX
T1-DSX/E1
V.35/
RS-449/
RS-530/
X.21
Video/Audio
Codec
RS-366