6-2
C
HAPTER
6: W
INDOWS
3.
X
T
ROUBLESHOOTING
Diagnostic tests are divided into three groups:
■
The Group 1 tests check the physical components,
connectors, and circuitry on the NIC.
■
The Group 2 Network Loopback Test (for the 3C509B-TPC
and COMBO NICs only) checks to see if the NIC can transmit
and receive data through the coaxial transceiver.
■
The Group 3 test (the Echo Exchange Test) tests to see if the
NIC can transmit and receive data while on the network.
If the NIC passes the group tests successfully, the NIC is
functioning correctly. If the problem remains, look at cabling,
software, driver configuration, and issues that can affect
network functionality.
Starting the DOS Configuration and Diagnostic Program
Follow these steps to run the Configuration and
Diagnostic Program:
1
Boot to DOS. (Use a DOS diskette.)
2
Insert
EtherDisk
diskette 2 in drive A.
3
Run the installation program. Enter:
a:install
The main menu is displayed, as shown in Figure 4-1.
4
Select
Configuration and Diagnostic Program
and
press Enter.
If multiple NICs are installed, each NIC is listed.
5
Select the NIC you want to test and press Enter.
You can also run the tests from the command line. At the system
prompt, enter:
3c5x9cfg run
Running the Group 1 Tests
Group 1 tests evaluate the physical components of the NIC.
A Group 1 test failure can indicate a faulty NIC.
For a description of each Group 1 test, press F1 to access Help.
In the Help screen, tab to the
Index
button and press Enter.
Use the arrow keys to move through the Index listings. Select
Test Definitions
and press Enter.
Book Page 2 Friday, June 11, 1999 3:02 PM
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com