Configuring the Ultra-WAN CSU/DSU Interfaces
57
Before beginning any of the procedures in this section, complete the
following tasks:
■
Attach a RJ-48C cable between the Ultra-WAN CSU/DSU interface
and an appropriate telco switch or external CSU.
■
Log on to the system with Network Manager privileges.
Configuring a
CSU/DSU Interface
for ISDN PRI Dial
Service
This section describes how to configure Ultra-WAN CSU/DSU interface for
ISDN PRI dial service.
To configure the Ultra-WAN CSU/DSU interface, follow these steps:
1
Set the FrameMode as appropriate for your setup:
SETDefault !<path> -PAth FrameMode = T1_SF | T1_ESF | E1_CRC4 |
E1_NOCRC
where <path> = 4A, 4B, 4C, or 4D.
The FrameMode parameter allows you to specify the frame mode. The
allowable values are the following:
2
Set the connector type as appropriate for your setup using:
SETDefault !<path> -PAth CONNector = E1_Pri |T1_Pri
where <path> = 4A, 4B, 4C, or 4D.
3
Set the Switch Type as appropriate for your setup using:
SETDefault !<path> -PAth SwitchType = ETSI | ATT5ESS | ATT4ESS |
DMS100 | DMS250 | NTT | NI2
The SwitchType parameter specifies the type of switch to which your
ISDN line is connected.
4
Set the LineEncoding as appropriate for your setup using:
SETDefault !<path> -PAth LineENCoding = B8ZS | AMI | HDB3
where <path> = 4A, 4B, 4C, or 4D.
The LineENCoding parameter specifies the transmission encoding
method for a serial line. The coding method you specify for the serial line
T1_SF
Superframe format T1.
T1_ESF
Extended Superframe format T1.
E1_CRC4
CRC-active E1.
E1_NOCRC
E1 without an active CRC.
Summary of Contents for 3C8S5007 - SuperStack II PathBuilder S500...
Page 12: ......
Page 24: ...24 CHAPTER 1 OVERVIEW OF THE PATHBUILDER SWITCH...
Page 36: ...36 CHAPTER 2 INSTALLING THE HARDWARE...
Page 48: ...48 CHAPTER 3 LOGGING ON AND PERFORMING ADMINISTRATIVE TASKS...
Page 66: ...66 CHAPTER 4 BASIC CONFIGURATION OF PORTS PATHS AND CONNECTORS...
Page 76: ...76 APPENDIX A SERIAL DEVICES...
Page 82: ...82 APPENDIX B TECHNICAL SUPPORT...
Page 106: ...106 APPENDIX C CONNECTORS AND CABLES...
Page 110: ...110 APPENDIX D CUSTOMIZING YOUR SOFTWARE...
Page 138: ...138 APPENDIX E TROUBLESHOOTING...
Page 142: ...142 APPENDIX F RELOADING THE SYSTEM SOFTWARE...
Page 166: ...166 APPENDIX H COMPLETING THE ATM CONFIGURATION...
Page 178: ...178 APPENDIX I COMMANDS AND PARAMETERS FOR ULTRA WAN CSU DSU INTERFACES...