Error LED Meanings
119
Meaning:
Possible read-only memory corruption; cannot seek file.
Action:
Reload the software. See Appendix F.
Meaning:
The software image file has been deleted or the boot source
and image names do not match.
Action:
Follow these steps:
1
At the monitor prompt, enter:
DF <path>
The default path is:
DF /primary
The image is called boot.ppc.
2
If the image has been deleted, reload the software using Appendix F.
3
If the image has a different name or is in a different directory, boot from
the image using:
BT [<path>]<filename>