Before wall mounting run the cable through the hole that you have prepared. Then
mark two mounting holes on the wall, through the amplifier front. Remove the
amplifier and drill the mounting holes. Use the plugs and screws included in the
delivery. Use a drill of the diameter of 6 mm. After fastening, cover the screws with
the blanks supplied.
Use the supplied connectors to connect the amplifier to the intercom and power
supply. The A connector is connected to the amplifier four-wire cable. Insert a special
intercom-connecting cable supplied with the amplifier and 12 V power supply outlets
to the B connector. Connect the special cable to the intercom and connect the power
supply to the mains. You can place the mated A and B connectors into the 2N IP
intercom cover. The connectors help you connect stripped cables. Open the
connector by pushing a thin screwdriver onto the white spots at its front and close the
connector by sliding the movable part through a side gap.
Finally, test the amplifier function using a suitable receiver for hearing impaired
persons or magnetic field communication tester. No other settings are required.
Specifications:
Supply voltage: 8 – 18VDC
Supply current at 12 V supply:
1 Ω load, full power output; 1.4 A, sine wave signal; 1 A, pink noise signal
8 Ω load, half power output; 550 mA, sine wave signal; 400 mA, pink noise
signal
no signal; 100 mA
standby; up to 10 mA
Transition to standby w/o signal: 10 s
Summary of Contents for 01353-001
Page 1: ...www 2n cz 2N IP Safety Emergency IP Intercom Installation Manual Version 2 13 ...
Page 41: ...2N TELEKOMUNIKACE a s www 2n cz 41 85 2N IP Safety Connectors PCB Version 555v3 ...
Page 56: ...2N TELEKOMUNIKACE a s www 2n cz 56 85 OVP overvoltage protection ...
Page 73: ...2N TELEKOMUNIKACE a s www 2n cz 73 85 3 3 Downloads Software 2N Network Scanner ...
Page 77: ...2N TELEKOMUNIKACE a s www 2n cz 77 85 4 1 General drawings Surface mounting ...