2N TELEKOMUNIKACE a.s., www.2n.cz
63/85
Status signalling:
Green LED
Red LED
Status
blinking
off
Operational mode
on
off
Activated output
blinking
blinking
Programming mode – waiting for initialisation
on
blinking
Error - wrong code received
Configuration:
Connect the
to the properly set intercom switch output;
2N Security Relay
®
refer to the
. Make sure that one LED at least on the
Configuration Manual
2N
®
is on or blinking.
Security Relay
Press and hold the
Reset button for 5 seconds to put the
2N Security Relay
®
device in the programming mode (both the red and green LEDs are blinking).
Activate the intercom switch using the keypad, telephone, etc. The first code
sent from the intercom will be stored in the memory and considered valid. After
code initialisation, the
will pass into the operational mode
2N Security Relay
®
(the green LED is blinking).
Caution
In case of resetting the factory default settings on a device with a
version of firmware 2.18 or higher it is necessary to reprogram the
using the instructions above.
2N Security Relay
®