IES4005M User’s Guide
21
C
H A P T E R
3
Management Cards
3.1 The MSC1401G Management Card
The MSC1401G aggregates the upstream service through optical PON connections and manages the
IES and the services of the line cards. The MSC1401G includes two SFP slots for single fiber GPON
interfaces with data rates of 1.244 Gbps upstream and 2.488 Gbps downstream. This card is hot-
swappable.
3.1.1 MSC1401G Front Panel
The following figure shows the front panel of the MSC1401G management card.
Figure 6
MSC1401G Front Panel
This table describes the front panel LEDs of the card.
Table 1
MSC1401G LED Descriptions
LED
COLOR
STATUS
DESCRIPTION
PWR
Green
On
The management switch card is installed and receiving power from the main
chassis.
Off
The management switch card is not receiving power from the main chassis.
SYS
Green
Blinking
The system is initializing.
On
The management switch card is on and functioning properly.
Off
The management switch card is not receiving power, is not ready or has
malfunctioned.
ALM
Red
On
An alarm has been detected on the IES. Examples of an alarm on the IES are
when the IES’s voltage or temperature is outside of the normal range.
Off
The IES has not detected an alarm on itself.
The following LEDs apply to the SFP slots.
LNK
Green
On
The IES is ranged.
Blinking
The IES is ranging.
Off
There is no connection to the PON.
Содержание IES4005M
Страница 4: ...Contents Overview IES4005M User s Guide 4...
Страница 13: ...13 PART I Introduction and Hardware Installation...
Страница 14: ...14...
Страница 20: ...Chapter 2 IES Chassis IES4005M User s Guide 20...
Страница 38: ...Chapter 4 Line Cards IES4005M User s Guide 38...
Страница 42: ...Chapter 5 Power Supply Unit IES4005M User s Guide 42...
Страница 46: ...Chapter 6 Fan Module IES4005M User s Guide 46...
Страница 58: ...Chapter 7 Cables IES4005M User s Guide 58...
Страница 64: ...Chapter 8 Hardware Installation IES4005M User s Guide 64 Figure 36 Removing a Line Card 1 2 3...
Страница 65: ...65 PART II Commands...
Страница 66: ...66...
Страница 78: ...Chapter 9 The CLI IES4005M User s Guide 78...
Страница 124: ...Chapter 13 Switch Features IES4005M User s Guide 124...
Страница 150: ...Chapter 20 MTU IES4005M User s Guide 150...
Страница 164: ...Chapter 23 Static Route IES4005M User s Guide 164...
Страница 192: ...Chapter 25 VLAN IES4005M User s Guide 192...
Страница 204: ...Chapter 26 VoIP IES4005M User s Guide 204...
Страница 210: ...Chapter 27 IEEE 802 1x Authentication IES4005M User s Guide 210...
Страница 211: ...211 PART III Troubleshooting Specifications Appendices and Index...
Страница 212: ...212...
Страница 220: ...Chapter 28 Hardware Troubleshooting IES4005M User s Guide 220...