![ZyXEL Communications EX3510-B1 Скачать руководство пользователя страница 270](http://html1.mh-extra.com/html/zyxel-communications/ex3510-b1/ex3510-b1_user-manual_943908270.webp)
Chapter 36 Diagnostic
EX3510-B1 User’s Guide
270
C
HAPTER
36
Diagnostic
36.1 Diagnostic Overview
The
Diagnostic
screens display information to help you identify problems with the Zyxel Device.
The route between a Central Office Very-high-bit-rate Digital Subscriber Line (CO VDSL) switch and one
of its Customer-Premises Equipment (CPE) may go through switches owned by independent
organizations. A connectivity fault point generally takes time to discover and impacts subscriber’s
network access. In order to eliminate the management and maintenance efforts, IEEE 802.1ag is a
Connectivity Fault Management (CFM) specification which allows network administrators to identify
and manage connection faults. Through discovery and verification of the path, CFM can detect,
analyze and isolate connectivity faults in bridged LANs.
36.1.1 What You Can Do in this Chapter
• The
Ping & TraceRoute & NsLookup
screen lets you ping an IP address or trace the route packets or
take to a host (
).
• The
802.1ag
screen lets you perform CFM actions (
).
• The
802.3ah
screen lets you configure link OAM port parameters(
36.2 What You Need to Know
The following terms and concepts may help as you read through this chapter.
How CFM Works
A Maintenance Association (MA) defines a VLAN and associated Maintenance End Point (MEP) ports
on the device under a Maintenance Domain (MD) level. An MEP port has the ability to send
Connectivity Check Messages (CCMs) and get other MEP ports information from neighbor devices’
CCMs within an MA.
CFM provides two tests to discover connectivity faults.
• Loopback test - checks if the MEP port receives its Loop Back Response (LBR) from its target after it
sends the Loop Back Message (LBM). If no response is received, there might be a connectivity fault
between them.
• Link trace test - provides additional connectivity fault analysis to get more information on where the
fault is. If an MEP port does not respond to the source MEP, this may indicate a fault. Administrators
can take further action to check and resume services from the fault according to the line
connectivity status report.
Содержание EX3510-B1
Страница 15: ...15 PART I User s Guide...
Страница 25: ...Chapter 1 Introducing the Zyxel Device EX3510 B1 User s Guide 25 Figure 8 Wall Mounting Example...
Страница 38: ...Chapter 3 Quick Start Wizard EX3510 B1 User s Guide 38 Figure 23 Wizard WiFi...
Страница 55: ...Chapter 4 Tutorials EX3510 B1 User s Guide 55 Tutorial Advanced QoS Class Setup...
Страница 60: ...60 PART II Technical Reference...
Страница 90: ...Chapter 7 Wireless EX3510 B1 User s Guide 90 Figure 51 Network Setting Wireless General...
Страница 154: ...Chapter 10 Quality of Service QoS EX3510 B1 User s Guide 154 Figure 92 Classification Setup Add Edit...
Страница 253: ...Chapter 31 Time Settings EX3510 B1 User s Guide 253 Figure 164 Maintenance Time...
Страница 265: ...Chapter 34 Firmware Upgrade EX3510 B1 User s Guide 265 Network Temporarily Disconnected...
Страница 283: ...Chapter 37 Troubleshooting EX3510 B1 User s Guide 283 7 Click OK when you are done and close all windows...