![background image](http://html1.mh-extra.com/html/zyxel-communications/enterprise-network-center/enterprise-network-center_manual_943713201.webp)
Chapter 8 Application
ENC User’s Guide
203
8.5.1 Configuring an Event
Use this screen to configure an event. To open this screen, click Add or select an entry and then
click Edit in the Event List section of the Application > RMON > Event /Alarm screen.
Figure 149
RMON > Event / Alarm > Event List Add/Edit
The following table describes the labels in this screen.
Edit
Select an entry in the Alarm List table and click this to modify it.
Remove
Select one or more entries in the Alarm List table and click this to delete them.
View Log
Select an entry in the Alarm List table and click this to display the falling and
rising thresholds as a table.
Parameter
Click this to view a list of threshold parameters and their settings.
check box
Select the check box of an entry and click Edit, Remove, View Log or
Parameter to take the action for the entry respectively. Select or clear the check
box at the table heading line to select or clear all check boxes in this column.
Interval (sec)
This field displays how often (in seconds) the ENC checks whether the parameter’s
value is within the set thresholds or not.
Sample Type
This field displays the method of obtaining the sample value (Absolute or Delta).
Startup Alarm
This field displays the alarm type (Rising, Falling, Rising & Falling Alarm) that
can be sent when this alarm is first activated.
Port Number
This field displays the number of a port or an interface to which this alarm is sent.
Variable
This field displays the name of the MIB field whose data is to be sampled.
Owner
This field displays the name of the application that created this entry.
Table 90
RMON > Event / Alarm (continued)
LABEL
DESCRIPTION
Table 91
RMON > Event / Alarm > Event List Add/Edit
LABEL
DESCRIPTION
Type
Select an event type.
Select LOG to generate a log when an associated alarm is generated.
Select TRAP to generate a trap when an associated alarm is generated.
Select NONE to not generate a log or trap when an associated alarm is generated.
Select LOG & TRAP to generate a log entry and trap when an associated alarm is
generated.
Community
This field displays the SNMP Get/Set community setting. You can use 1-31
printable ASCII characters. Spaces are allowed.
Содержание ENTERPRISE NETWORK CENTER
Страница 2: ......
Страница 6: ...Document Conventions ENC User s Guide 6 Server DSLAM Firewall Switch Router ...
Страница 8: ...Contents Overview ENC User s Guide 8 ...
Страница 15: ...15 PART I User s Guide ...
Страница 16: ...16 ...
Страница 46: ...Chapter 1 Web Configurator ENC User s Guide 46 ...
Страница 83: ...83 PART II Technical Reference ...
Страница 84: ...84 ...
Страница 86: ...Chapter 3 Dashboard ENC User s Guide 86 Figure 58 Dashboard B C D E A ...
Страница 92: ...Chapter 3 Dashboard ENC User s Guide 92 ...
Страница 186: ...Chapter 7 Report ENC User s Guide 188 ...
Страница 258: ...Chapter 9 Maintenance ENC User s Guide 262 ...
Страница 266: ...Appendix A Product Specifications ENC User s Guide 270 ...
Страница 286: ...Appendix C Pop up Windows JavaScript and Java Permissions ENC User s Guide 290 ...
Страница 296: ...Appendix D Open Software Announcements ENC User s Guide 300 ...