8–6
S16 Test status register; default: 0:
Z1
001
32
Profile 1 as active settings; also active after
the next power turn-on.
Z2
010
64
Profile 2 as active settings; also active after
the next power turn-on.
Z3
011
96
Profile 3 as active settings; also active after
the next power turn-on.
Z4
100
128
Profile 4 as active settings; also active after
the next power turn-on. (Default)
*C0
(4,3)
00
0
10-bit character length. (Default)
*C1
01
8
11-bit character length.
*C2
10
16
9-bit character length.
*C3
11
24
8-bit character length.
Note:
Character length includes start bit, data bits, parity, and stop bit(s).
Code
Bits
Bin.
Dec.
Description
(2)
0
0
1 stop bit. (Default)
1
4
2 stop bits.
(1,0)
00
0
Even parity.
01
1
Odd parity.
10
2
No parity. (Default)
Code
Bits
Bin.
Dec.
Description
&T0
0
No test is in progress. (Default)
&T1
1
Analog loopback test is in progress.
&T2
2
Reserved.
&T3
3
Local digital loopback test is in progress.
&T6
6
Remote digital loopback test is in progress.
&T7
7
Remote digital loopback with self-test is in
progress.
&T8
8
Analog loopback with self-test is in progress.
Note:
This S-register may not be set directly and may not be read while a
test is in progress. Use the
AT&Tn
command codes.
Code
Bits
Bin.
Dec.
Description
Содержание 2864 Series
Страница 1: ...i 2864 Series Modem User s Manual Document No 8406 Rev 1 0 ZyXEL COMMUNICATIONS CORPORATION...
Страница 8: ...viii...
Страница 26: ...1 10...
Страница 42: ......
Страница 50: ...3 14...
Страница 66: ...5 10...
Страница 110: ...8 24...
Страница 128: ...10 6...
Страница 134: ...11 6...
Страница 148: ...13 10...
Страница 204: ...16 28...
Страница 224: ...21 4...
Страница 230: ...23 4...
Страница 234: ...24 4...
Страница 246: ...A 2...
Страница 248: ...B 2...
Страница 252: ...D 2...
Страница 256: ...E 4...
Страница 267: ......