13.
The display will appear similar to the example above. Turn the
Silver Select Knob
to “yes” to
use vacuum in your program or “no” if you do not wish to use vacuum in this program.
Press the
“Next”
button
to continue. If your selection in this step was “no” the display has returned to the
ready select menu screen and you are finished adding this program. If your selection in this step
was ”yes” continue with the next step.
14.
The display will be similar to the above example. Turn the
Silver Select Knob
to select a
temperature for the vacuum to start. The vacuum pump will be turned on at this temperature.
Press the
“Next”
button
to continue.
15.
“RELEASE VAC XXXC” is now displayed. Turn the
Silver Select Knob
to select a temperature
to release the vacuum.
Press
the
“Next”
button
to continue. The program has been saved and the
display will now return to the ready select Menu screen.
Note: If you wish to hold vacuum during the final temp hold, you must use the Special
Firing cycle described on page 30.
Press Firing Cycle Program
The following procedures describe how to enter a pressing program:
1.
Press
the
“Change Program”
button
2.
Turn the
Silver Select Knob
until “Add a Program” is now displayed.
3.
Press
the
“Next”
button to add a program. “Add” will be displayed. Turn the
Silver Select
Knob
to find the number you want to add your new program into. If you select a number that
already has a program entered, you will destroy the existing program and replace it with the new
one. Press
the
“Next”
button to continue.
4.
“
PORCELAIN TYPE
”
will be displayed. Turn the
Silver Select Knob
to find the firing cycle
for the “
Press
” program.
5.
Press
the
“Next”
button to continue.
6.
”ENTER PROG NAME”
will be displayed on the top line and the program number with the
program type selected previously will be on the second line. Turn the
Silver Select Knob
to
change the underlined characters. Any letter, number, space or special character can be selected.
Pressing the
“Next”
button will step the select cursor to the next character position. Pressing the
“last” button will move the cursor to the previous character positions. When all eight characters
have been entered the display will step forward to the next parameter.
7.
“ENTRY TEMP”
displays the current selected entry temperature. Turn the
Silver Select Knob
tot he required entry temperature. This is the temperature you wish the furnace to be when the
porcelain enters the muffle. It is now displayed in Centigrade or Fahrenheit.
8.
Press
the
“Next”
button to continue.
DURING HEAT
UP
START VAC 0°C
Содержание Vario Press 100
Страница 6: ...Vario Press 100 Operations Manual VP_0206E 6 Chapter One Getting Started ...
Страница 13: ...Vario Press 100 Operations Manual VP_0206E 13 Chapter Two Special Functions Menu ...
Страница 24: ...Vario Press 100 Operations Manual VP_0206E 24 Chapter Three Change Program Menu ...
Страница 37: ...Vario Press 100 Operations Manual VP_0206E 37 Chapter Four Run Program Menu ...
Страница 43: ...Vario Press 100 Operations Manual VP_0206E 43 Chapter Five Maintenance ...
Страница 56: ...VP_0206E ...