10
Seite
Seite
Page
Enter
003-PULSE MC CERAMAY
450C
Edit “ 063-PULSE MC DENTIN 1 “
Program type Standard
-Start temp
450C
-Pre dry
Yes
-Pre dry time
3:00
-Closing time
3:00
-Heat rate
55C
-Final temp
820C
-Hold time
1:00
-Opening time
1:00
-Vacuum
Yes
-Vacuum Star
450C
-Vacuum End
820C
Esc
Start temperature
Temperature in the
firing chamber at which the program starts.
Pre-dry
Selecting “YES” activates the special pre-
drying program.
Pre-dry time
Enter a time. In this section, the lift
identifies a predefined position for the entire
time, depending on the heat radiated by the
firing chamber. The object can thus be pre-dried
at a constant temperature.
Closing time
Time in which the lift moves in 10
increments into the firing chamber.
Heat rate
Temperature increase per minute in order
to reach the final temperature.
Final temperature
Temperature at which the cera-
mic is sintered.
Hold time
Period for which the ceramic is maintai-
ned at the final temperature.
Opening time
Decent time of the lift from the
chamber to the fully open position.
Vacuum
Selecting “YES” activates the vacuum
parameter (firing under vacuum).
Vacuum start
Temperature at which the vacuum
pump begins to evacuate the firing chamber.
Vacuum end
Temperature at which the vacuum
release occurs.
Edit done?
Saving of the program.
Program types - 2:
Standard Program
A standard firing management in accordance with the guidelines for the dental ceramics available on the market.
1 Operation
Содержание VARIO 200
Страница 1: ...www zubler de VARIO 2 20 00 0 Operating instructions 01 2014 en Ceramic Furnace...