ZXC10 CBTS I2 Installation Manual
62
Confidential and Proprietary Information of ZTE CORPORATION
75
Ω
E1 cable connection
Connect 75
Ω
E1 cable End A (left end in Figure 43) to BSC E1 socket
of conversion board at CBTS top. Connect E1 cable End B (right end in
Figure 43) to corresponding E1 interface of conversion board on feeder
shelf.
Table 12 describes 75
Ω
E1 cable internal connections in detail.
T
A B L E
1 2
-
7 5
Ω
Ω
Ω
Ω
E 1
C
A B L E
I
N T E R N A L
C
O N N E C T I O N S
Signal
definition
IN0
OUT0
IN1
OUT1
End A pin
number
22 23
24 25
1 2
3 4
Cable number 1-1-internal
1-1-external
1-2-internal
1-2-external
1-3-internal
1-3-external
1-4-internal
1-4-external
Signal
definition
IN2
OUT2
IN3
OUT3
End A pin
number
5 6
7 8
9 10
11 12
Cable number 1-5-internal
1-5-external
1-6-internal
1-6-external
1-7-internal
1-7-external
1-8-internal
1-8-external
Signal
definition
IN4
OUT4
IN5
OUT5
End A pin
number
13 14
43 44
39 40
41 42
Cable number 2-1-internal
2-1-external
2-2-internal
2-2-external
2-3-internal
2-3-external
2-4-internal
2-4-external
Signal
definition
IN6
OUT6
IN7
OUT7
End A pin
number
35 36
37 38
31 32
33 34
Cable number 2-5-internal
2-5-external
2-6-internal
2-6-external
2-7-internal
2-7-external
2-8-internal
2-8-external
Note:
’1-1-internal and 1-1-external’ stands for internal and external conductors of
the 1st core in 8 core cable respectively.
Содержание ZXC10 CBTS O1
Страница 4: ...This page is intentionally blank ...
Страница 10: ...This page is intentionally blank ...
Страница 162: ......