ZXC10 CBTS I2 Installation Manual
148
Confidential and Proprietary Information of ZTE CORPORATION
Frequency Range Selection
Take following steps to select a frequency range using SiteMaster:
1.
Press <ON
>
to turn on SiteMaster meter.
2.
Press <FREQ
>
on the main menu.
3.
Press <F1> on the [Frequency] menu.
4.
Input [Lower
]
frequency, such as 825 MHz, and press <Enter
>
for
confirmation.
5.
Press <F1> on the [Frequency] menu.
6.
Input [Higher] frequency, such as 880 MHz, and press <Enter>for
confirmation.
7.
After confirmation, press [Main] to return to the main menu.
SiteMaster Check
Check the SiteMaster for frequency, environment and feeder parameters
changes. Take following steps to check:
1.
Before check, ensure that input frequency range in SiteMaster is
correct.
2.
Press <STARTCAL> to start check.
3.
Press <Measuring OPEN>, <Measuring SHORT> and <Measuring
Load> as indicated to complete the check.
4.
Include the extension cable attached with the meter to ensure
measurement accuracy.
Feeder Input Parameters
Take following steps to input feeder parameters:
1.
Press <DIST>
2.
Press <MORE>
3.
Press <LOSS> to enter input feeder loss (dB) per meter. Press
<Enter> for confirmation.
4.
Press <PROP V> to enter relative transmission rate. Press <Enter> for
confirmation.
5.
Press <Main> to return to the main menu.