Chapter 8 Trunk Cable Installation
8-7
Crimping
tube
Hot shrink
tube
Cable
connector
sheath
Crimping
pliers
14
3
6
Fig. 8.2-3 Assembling DDF Coaxial Cable Plug
3. Trunk cable test
The internal conductors of the connector at both ends and the inner conductors
of the coaxial cable should be soldered securely without dry joint.
In the connector at both ends, the internal conductors are conductive and the
external conductors are conductive, while the internal and external conductors
should not be shorted.
8.3 Converting 75
Ω
Trunk Cable to 120
Ω
Trunk Cable
Currently the impedance converter coded "5160087" is used to convert the 75
Ω
trunk
cable into the 120
Ω
trunk cable. The following section describes the impedance
converter.