` Use the * and * keys to select which entry is highlighted.
Press enter to boot the selected OS, `e' to edit the commands
before booting or `c' for a command-line.`
6. At the prompt ("bash-4.3#"), run this command to erase all files and load factory
configuration, without quotation marks (‘’): 'apply_settings --factory-and-cleanlogs
-f -h'
7. Wait the following message:
Apply factory settings completed.
INIT: Switching [ ... ] reboot: System halted
8. Power off the unit.
Hard Removal - Secure Erase
Erase the nonvolatile memory of Nodegrid unit using the following procedure:
1. Shutdown Nodegrid unit and power it off
2. Remove Nodegrid unit from the network (disconnect Ethernet cables of the unit)
3. Disconnect any USB storage device and USB network device connected to
Nodegrid unit
4. Access Nodegrid unit with one of the following options:
a. Nodegrid console port using a RJ-45 console adapter and a straight-
through network cable connected to a terminal or workstation.
b. HDMI port and USB port connected to an HDMI monitor and USB
keyboard.
5. Power on the unit
6. Press the 'Esc' key after BIOS setup page appears on your screen