CLI rename port 2 example
Serial Devices
The Nodegrid Platform supports RS-232 Serial connections thought the available Serial and
USB interfaces. The ports are automatically detected and displayed in the Devices menu
and can directly be used. Each port needs to be enabled and configured to provide access
to the target device.
Before configuring the Nodegrid port check the console port settings of the target device
with the manufacturer. Most devices use settings of 9600,8,N,1,N which is the default for the
port
The
Nodegrid Console Server S Series
support advanced auto-detection which simplify the
configuration process, by automatically detecting the cable pinout (Legacy and Cisco) and
connection speed.
Configure Serial Devices - WebUI
Navigate to
Managed Devices:: Devices
Click on the port or select the port and click on
Edit
. Multiple Ports can be selected
Confirm the values for:
Baud Rate
set it to the correct speed matching the target device settings or to
Auto
Parity
possible values are:
None
(default),
Odd
, or
Even
Flow Control
possible values are: None (default), Software, Hardware
Data Bits
possible values are:
5
,
6
,
7
,
8
(default)
Stop Bits
possible values are:
1
RS-232 signal for device state detection
possible values are:
DCD
(default),
None
,
CTS
Mode
possible values are:
Enabled
,
On-Demand
,
Disabled
Optional, settings which control the display and behavior of the device can be
adjusted at this time. See
for more details
[admin@nodegrid devices]# rename ttyS2
[admin@nodegrid {devices}]# set new_name=Port2
[admin@nodegrid {devices}]# commit
Содержание Nodegrid Bold SR
Страница 1: ......
Страница 2: ...User Guide Nodegrid Serial Console Nodegrid Services Router Nodegrid Bold SR Nodegrid Manager...
Страница 11: ......
Страница 211: ......
Страница 220: ...Case of 48VDC supply Case of 48VDC supply...
Страница 227: ...ZPE Systems Inc 46757 Fremont Blvd Fremont CA 94538 USA www zpesystems com...