Default Sequence
Escape Sequence
^Ec
CTRL+SHIFT+E c
Power Control Key
^O
CTRL+SHIFT+O
This options allows users to send a break signal via the ssh console session. The function
can be enabled on a per device basis and the break sequence be set.
WebUI
Navigate to
Managed Devices:: Devices
Click on the Target Device to access its settings
Tick the box besides
Enable Send Break
Adjust the
Break Sequence
as needed
CLI
Navigate to
/settings/devices/<Device Name>/access
set
enable_send_break
to
yes
adjust
break_sequence
as needed
commit
the changes
[admin@nodegrid /]# /settings/devices/Device_Console_Serial/access/
[admin@nodegrid /]# set enable_send_break=yes
[+admin@nodegrid access]# set break_sequence=~break
[+admin@nodegrid access]# commit
Escape Sequences
Escape Sequences allow users to esacpe from the current session and to bring up a menu
or to directly perform specific tasks like bring up the power menu.
The Nodegrid supports two escape sequences. One for the normal session menu and
secound for the power menu which allows for direct power controll of a target device if this
is setup accordingly. (See: Power Control)
Both escape sequences are preset with a default value which can be changed if needed.
WebUI
Navigate to
Managed Devices:: Devices
Click on the Target Device to access its settings
Adjust the
Escape Sequence
or
Power Control Key
as needed
Содержание Nodegrid Bold SR
Страница 1: ......
Страница 2: ...User Guide Nodegrid Serial Console Nodegrid Services Router Nodegrid Bold SR Nodegrid Manager...
Страница 11: ......
Страница 211: ......
Страница 220: ...Case of 48VDC supply Case of 48VDC supply...
Страница 227: ...ZPE Systems Inc 46757 Fremont Blvd Fremont CA 94538 USA www zpesystems com...