background image

GDP-32

24 

INSTRUCTION MANUAL

 

September 2015 

Section 4, Page 20 

GDP-32

24

 

4.16

 

DATA ACQUISITION 

After all the setup parameters, and field connections have been confirmed, press 

 to start 

data  acquisition.    Some  field  programs  provide  a  Time  Schedule  feature  to  allow  for  an 
automated sequence of data acquisition cycles.   

Immediately  after  pressing 

,  the  GDP  will  perform  the  requested  gaining.    When  the 

selected gain method has completed, the GDP acquisition will synchronize with the timing card 
and  indicate  that  it  is  taking  data.    At  frequencies  of  2  Hz  and  above,  no  other  indication  of 
collecting data will be observed, as the GDP is using its full resources to read the A-D cards and 
store  the  raw  data  into  the  computer  memory.    For  1  Hz  and  below,  a  progress  bar  will  be 
displayed  showing  the  time  left  for  taking  data.    Intermediate  results  and  SEM  values  will  be 
displayed for every 2 seconds of acquired data in order to evaluate the process.  When data has 
been acquired, the final results will be calculated and displayed.   

When taking a single stack of data, the GDP will display the message “

Press ESCAPE to 

discard,  CONTINUE  to  save  –  Hit  Key

”,  make  an  audible  signal,  and  then 

pause for the operator's response.  The operator must then respond, and the data will be written to 
the flash card or discarded, based on their review of the results.  After responding, the GDP will 
write the data, make an audible signal, and be Ready for further acquisition.   

If  any  error  occur  during  acquisition,  the  receiver  will  halt,  make  an  audible  signal,  post  a 
message  identifying  the  error,  and  pause  until  the  operator  presses  a  key  to  acknowledge  the 

error.    Additional  information  about  the  error  may  be  obtained  by  pressing 

,  to 

view the message history.  When running an automated Time Schedule, the receiver will not halt 
for most errors.  Instead, the Schedule will attempt to recover by advancing to the next schedule 
line.   

To cancel data acquisition, to limit the number of stacks to acquire, or to cancel a Time schedule, 

press 

.   

 

Enter

Enter

SELECT DN

End

Es c ape

Содержание GDP-32

Страница 1: ...ANUAL SYNCHRONIZATION 10 4 8 SET TIME 11 4 9 SYNC CHK 13 4 10 FIELD SURVEY PROGRAM 14 4 11 JOB_INFO SCREEN 15 4 12 LINE SETUP 16 4 13 ACQUISITION CONFIGURATION 17 4 14 CHANNEL TABLE 18 4 15 CHECK FIEL...

Страница 2: ...ck Field connections Acquire Data Check Data 6 Transfer Data Simple menus make operating the GDP 3224 straightforward The easiest way to become familiar with the receiver operation is to try the vario...

Страница 3: ...r 2015 CURSOR POSITION To position the cursor on the LCD display use the Cursor Control Keys or and To cycle through available options labels and numbers use the Rotary Entry Keys and Pg Dn NEXT FIELD...

Страница 4: ...ith an XMT transmitter controller both the receiver and XMT should be powered on for at least an hour before syncing and acquiring data Press the button located on the Front Panel The unit beeps and t...

Страница 5: ...sure all the channels to be calibrated are turned on 3 Set the frequency to the lowest frequency that will be used during the survey 4 Select the notch filter to be used for the survey Note It is good...

Страница 6: ...ecially as the environment changes will provide the best results Refer to Section 6 Setup and the sections for specific programs for more information about calibration and when to use METHOD 1SHOTCAL...

Страница 7: ...closely to confirm and identify and real problem See the System Check section of this manual for more information FREQ Set to the lowest frequency to be used for the job CYCLES At least 2 cycles for t...

Страница 8: ...GDP 3224 INSTRUCTION MANUAL September 2015 Section 4 Page 8 GDP 3224 0404a_24SYSCHK_Quick For more detailed instructions see Section 8 System Check...

Страница 9: ...zation the receiver should be connected to either a GPS antenna or to an XMT transmitter See Section 6 Receiver Setup for more information about making the connections to a transmitter controller 0405...

Страница 10: ...the receiver and XMT should be powered on for at least an hour before running SYNC If a fast beep sounds while pressing any of the crystal adjust keys no more adjustment is available on that particul...

Страница 11: ...the and keys to make adjustments After making adjustments move the cursor back to the MODE field and make sure the GPS Local Time appears correct If not adjust the Local Time Differential setting When...

Страница 12: ...GDP 3224 INSTRUCTION MANUAL September 2015 Section 4 Page 12 GDP 3224 0408b_24SYNC_TimeManl...

Страница 13: ...the internal reference Set channel 2 comp field to XMT and connect the channel inputs to the XMT Sync Out ports Turn Off all other channels not connected to a synchronized signal Press 0409a_24SNCCHK...

Страница 14: ...eters can be entered directly on the Main Menu screen Various submenu screens are accessed directly from the Main menu for entering more specific job or special setup parameters Functions such as Cali...

Страница 15: ...job information submenu where Operator Transmitter and other job based data are entered Programs such as TEM also use this screen to enter loop antenna configurations delay times and other data which...

Страница 16: ...all programs contain all the fields listed below some programs contain additional fields but all the fields in this portion of the screen should be inspected and modified if necessary TIME SERIES Set...

Страница 17: ...if necessary FREQ Select the frequency to analyze CYCL Set the number of cycles to average STACKS Set the number of repetitions of data acquisition to perform Each stack will be recorded as its own b...

Страница 18: ...l parameters Some examples are Note Refer to the appropriate Survey Program chapters for more information on setting up channels Any designator other than OFF will turn on channels for all programs wi...

Страница 19: ...ELD CONNECTIONS The Channel Table is also used to verify electrode and coil field connections prior to data acquisition Pressing starts the Contact Resistance CRES function to measure the resistance o...

Страница 20: ...to evaluate the process When data has been acquired the final results will be calculated and displayed When taking a single stack of data the GDP will display the message Press ESCAPE to discard CONT...

Страница 21: ...mode Each program has its own cache viewing features and procedures Refer to the appropriate field survey manual for more information Press the function key to return to Data Acquisition mode 0417a_2...

Страница 22: ...screen press to start the connection 0418a_GDPNET_ManualStart Enter an IP address consistent with the address of the PC or laptop The first 3 octets for the receiver address should be set to match tho...

Страница 23: ...er to the Local Area Network hub with a standard cable From the Zonge Logo screen press to start the connection Press to select the AUTOMATIC settings 0418c_GDPNET_NetStart Press to initiate the conne...

Страница 24: ...attributes and properties from the PC or laptop computer s File Explorer This can make the GDP system unstable File attributes on the GDP must NEVER be set to Read Only or Hidden FILE TRANSFER Files c...

Отзывы: