ZSI-330 User Manual
Issue 01
Page 26 of 30
Diagnostics
LEDs
Each serial communications port on the ZSI-330 has LEDs to indicate any Transmit and Receive activity.
The CPU LED maintaining a steady 1Hz flash indicates that the controller has successfully powered up. It
also indicates when configuration mode is active with a faster flash rate.
The Line Status LED indicates the usage of the ISDN line.
•
1Hz flash with the LED on for only a short period indicates the ISDN line is idle
•
1Hz flash with the LED off for only a short period indicates that the ISDN line is connected
•
Fast flash rate indicates that the ZSI-330 is attempting to make a call.
Commands
These commands, which can be issued by Mpower, are included in this document to assist in the diagnosis
of problems.
The use of these commands is at the users own risk and is subject to change without notice.
Fn
Name
Purpose
Notes
0
Initialise
Initialise all modules
1
LoadDefaultConfiguration
Reset configuration.
All static configuration is set to factory defaults
2
StandaloneTestMode
For factory use only
3
InitialiseCmdHandler
Re-initialise command stack.
Discards all current commands. May cause memory loss. For
debugging only
4 FlushCommandStack
Clear all commands from the
stack
Discards all current commands. Will stop CPU LED flashing.
5
InitialiseBothOSD
Re-initialise the display chips
6 ScreenModeInternalSync
Sets the display to internal
sync
Video input will no longer be displayed
7
ScreenModeTranslucent
Selects translucent text mode
8
ScreenModeOpaque
Selects opaque text mode
9 InitialiseMonitor
Reselect the current camera or
sequence
10 ReInitialisePC2Port
Re-initialise internal control
port
Resets uart & discards commands
11 ReInitialisePC3Port
Re-initialise
clear
data channel
Resets uart & discards commands
12
ReInitialiseZvmPort
Re-initialise ZoneVu port.
Resets uart & discards commands. Required after changes to
comms settings.
13
ReInitialiseZvrPort
Re-initialise ZVR port.
Resets uart & discards commands. Required after changes to
comms settings.
14
InitialiseMMT
Initialise 8121 board
Reloads all configuration into 8121, after power-up delay
15
InitialiseDialup
Initialise call status
Assumes call status is idle
16 InitialiseContactAlarms
Reset the status of alarm
inputs
17
InitialiseControl
Reset camera control records
Assumes no camera control held. Restarts control timeout.
18
FlushAlarmQueue
Remove all alarms from queue
No notification is sent to keyboards
19
InitialiseAlarms
Re-initialises alarm module
Discards all alarms. May cause memory loss – for debugging only.
20
RestartApplication
Re-starts application
Simulates power-up
21
RestartMMT
Re-starts 8121 board
Uses serial command to simulate power-up reset.
22
InitialiseTelemetry
Re-initialise telemetry module
Clear receiver alarm status & latched function log.
MEYERTECH LIMITED
Z
S
I
-
3
3
0