Switch
If enabled, the monitor will be switched, to view the selected camera. If multiple active alarms have the switch enabled,
the most recent alarm will be displayed.
Default =
No
Record
If enabled, the video will be recorded immediately the alarm is triggered. This feature is intended to capture the vital
seconds after an alarm, whilst a connection is made to the remote control room.
The most recent alarm event only can be replayed by the remote operator.
Default =
No
Report
Local operator
The MAC address of the keyboard to report the alarm to. Other options =
All, None, PC
Default =
All
Remote site
The site number of the control room to report the alarm to. If enabled, the remote site is automatically dialled,
to report the alarm. A phone number is required for the site number in the
Telephone
section.
Default =
None
Enabled =
No
Relay
Action
Select a state for one of the auxiliary relay outputs. Options:
None, Open, Close, Pulse.
Pulse
closes the relay for 1 second.
Default =
None
Relay number
The auxiliary relay number, from 1 to 4.
Default =
None