25
Zonar 18” Discrete I/O Wiring Details
• 5 Inputs (depending on application, all inputs may not be used)
• 20 AWG wire gauge
WARNING:
Observe all general and specific warnings in regards to electrical
installations at the beginning of this guide.
When in doubt consult the specific vehicles manufacturer for electrical
installation instructions.
Do not connect to multiplex wiring.
The purpose of this schematic is to add a relay controlled by the existing vehicle controlled circuit
such that it enables the correct voltage to the discrete I/O inputs.
Zonar Discrete I/O System
DISCRETE I/O SYSTEM
INSTALLATION
Optional Fuse (Not Supplied)
Note:
The monitored vehicle circuit
should always be electrically protected.
In the event this circuit is not properly
electrically protected, install 1 Amp fuse
as indicated to the left.
Electrical fuses
should be installed as close as possible
to the source of power.
Zonar V3™
Additional Circuit
18” Discrete IO
Cable Assy.
1 Amp
Fuse
Relay Load Circuit
Relay Related
Fuse
Monitored Devise
(Load)
Vehicle Fuse
Panel
ON/OFF
Switch
Relay Control
Circuit
Vehicle - 8 to 30 VDC Source
Existing Circuit
Fig. 25-1
3) Do not connect to sub-3 second cycling circuits.
4) Activity states: 0 Volts (Normally - Stowed, Off, Retracted), 8-30
Volts (Temporarily - Deployed, On, Extended).
5) Route all cables and wiring away from high voltage and RFI circuits.
These may induce false signals.
Notes:
1) Suggested uses -
Door: Open/Closed
Plow: Up/Down
PTO: On/Off
Sweeper: On/Off
Light: On/Off
Arm: In/Out
2) Do not connect to pulsing, flashing, or high cycle circuits
(e.g., Flashers, Foot Brake, Turn Signals). Doing so may
result in higher data rate fees.