Cooling fan

: fan for heat dissipation of power supply 

Special output connector: 

interface to light source via standard interface 

Power supply interface

input 100-220VAC

47-60Hz    Max 10A

 

Power input /insurance / switch

The power switch of the whole power supply is controlled by the switch   

Ground

The grounding interface of the power supply equipment can avoid the damage of static electricity 

and other equipment 

External control selection and input

 

When the switch "INT" is selected before the machine is energized, the light source switch is controlled by the 
start  button  of  the  front  panel.  When  the  switch  chooses  "EXT"  before  the  machine  is  energized,  it  is 
controlled by the BNC port of the rear panel After the panel is connected with the high level BNC (5V), light 
source start, front panel switches lit, the rear panel BNC is low (0V), the light source is shut off, the front panel 
switches  flashing  light  fan  to  work  off  after  5  minutes,  the  fan  can  start  again  after  the  closure  of  the  light 
source, when the time no, BNC high level is invalid.

 

 
 

4.3 Operation Guide   

1

Standard interface connection light source operation method: 

1. Connecting the power supply line, the standard interface connects the light source, closes the master switch, 
the front panel displays the voltage current value and the working status indicator.   
2. Press the setting / actual current switch to make the Set light on. Press the power inside / outside control 
button to the indicator light Local, indicating that the current is adjusted by the panel current adjustment knob. 

Power input 

/insurance / switch

Cooling outlet 

External control 

selection and input

Ground 

Special output 

connector

Содержание GLORIA-X500A

Страница 1: ...GLORIA X500A 500W Xenon Light Source System Operation Manual Version 1 0 2015 4 Zolix Instruments Co Ltd...

Страница 2: ...ing 3 3 1 Light path 3 3 2 Xenon lamp bulb installation method 4 3 3 Light source housing operation guide and safety precautions 6 3 3 1 Adjustment before the xenon lamp is lighted 6 3 3 2 Adjustment...

Страница 3: ...ency and high pressure The high voltage short arc spherical xenon lamp can output the point light source and strong and stable continuous spectrum from UV to NIR The visible light is approximate to th...

Страница 4: ...MAX power 500W Parallel light spot dia 44mm theoretical value is 50mm from exit Divergence half angle 1 54 Spectrum range 200 2500nm 250 1800nm Lamp adjustment 2D Reflector adjustment 3D Xenon lamp l...

Страница 5: ...ix com cn 3 Xenon lamp light source housing 3 1 Light path In the xenon lamp housing the output light energy is enhanced by spheric reflect mirror behind the xenon lamp Collimating lens collects the l...

Страница 6: ...w zolix com cn E mail info zolix com cn 3 2 Xenon lamp bulb installation method Caution You must make sure the power supply is turned off when you mounting the xenon lamp Side plate Remove the side pl...

Страница 7: ...he light source housing 3 Before installation you d better swab the lamp with alcohol for fear that the transmittance and life time will not be detracted by the sweat on hand oil pollution or dusty co...

Страница 8: ...n lamp is lighted 1 Adjust 3 reflector turret at the same time make the diatance between light cup underside and adjusting bracket base is about 3mm 2 Reove collimating lens barrel then adjust shift k...

Страница 9: ...the vertical adjusting knob which can make the lamp bulb self emission light spot moves up and down relative to the center of light tube solid line spot as shown above figure 2 make the light bulb gl...

Страница 10: ...radiation which can cause permanent damage to unprotected skin and eyes Therefore never look directly into the output beam any diffuse reflection or any specular mirror reflection even for a short pe...

Страница 11: ...ition 25A 20V Current accuracy 0 1 Power regulation rate 0 05 Load regulation rate 0 05 Ripple Current 10mA Voltage 20mVp p 4 2 Function Introductions The function of front panel and rear panel of HPS...

Страница 12: ...the knob and setting button the current value is displayed on the current display table Front output interface if the light source is connected to the front panel interface the 1 and 2 pin interfaces...

Страница 13: ...that the user can set the output current size at this time Cur When the setting actual current switching is up the Cur light is on indicating that the current meter shows the output current of the us...

Страница 14: ...e BNC port of the rear panel After the panel is connected with the high level BNC 5V light source start front panel switches lit the rear panel BNC is low 0V the light source is shut off the front pan...

Страница 15: ...be used to connect the light source and the main switch is closed The front panel displays the voltage current value and the working status indicator 2 Press the current inside outside the selection...

Страница 16: ...ructions for products Warning The interior part of the light source contains very intense ultraviolet light It can cause serious damage to the eyes and skin Never look directly into the output beam Xe...

Страница 17: ...e responsible for repairing or replacing the same type of product If artificial operative errors or unauthorized use or unauthorized access to repair or natural disasters and other irresistible factor...

Страница 18: ...her cannot be provided the product label serial number is the warranty start month note If the manufacturing month is January 2002 the warranty period to the end of January 2003 3 Warranty service obj...

Страница 19: ...diator cap 2 LSH500A 043 Anode Gland Nut 3 LSH500A 048 STRAP made in china 1 4 LBA XBO500HOFR OSRAM XBO500WHOFR Lamp bulb installion attachment 1 LSH500A 041 OSRAM radiator cap 2 LSH500A 044 Anode ply...

Отзывы: