The current value of the light source is set by the current adjusting knob, and is observed on the current display 
table. After reaching the set value, the button is pressed again to display the actual current value state 
3. Press start switch and output current to light.     

2

Front panel interface connection light source operation method:

 

1.  Connect  the  power  supply  line,  the  front  panel  output  positive  and  negative  poles  connected  to  the  light 
source, closed the main switch, front panel display voltage and current value and work status indicator. Notice 
that the 1 and 2 pin interfaces of the connector on the rear panel must be short circuited, otherwise the power 
supply will be protected. 
2. Press the setting / actual current switch to make the Set light on. Press the power inside / outside control 
button to the indicator light Local, indicating that the current is adjusted by the panel current adjustment knob. 
The current value of the light source is set by the current adjusting knob, and is observed on the current display 
table. After reaching the set value, the button is pressed again to display the actual current value state.     
3. Press the soft start switch and output current to light the light. 

3

Operation method of light source controlled by external voltage input:

 

1. Connecting the power supply line, the front panel or rear panel standard interface can be used to connect the 
light source, and the main switch is closed. The front panel displays the voltage current value and the working 
status indicator.   
2.  Press  the  current  inside  /  outside  the  selection,  to  the  indicator  Remote  indicator  light,  access  to  0~5V 
external input control side, through the external regulation of the control current output. 
3. Press the soft start switch and output current to light the light. 

4

Switch operation of external control power supply:

 

1.  Before  the  machine  is  energized,  switch  the  power  switch  of  the  rear  panel  to  the  "EXT"  position.  And 
connect the rear external control BNC cable

 

2. Powering the machine 
3. Setting current according to the above current settings 
4. After the external control BNC cable input +5V, light source start, fan work; input 0V, light source closed, 
fan continue to work for 5 minutes; 5 minutes after the fan closed, at this time the BNC input +5V, the light 
source can start again. When the light source is closed less than 5 minutes, that is, when the fan is still working, 
restart again invalid. 
 

5  Unpacking Procedures   

(1) 

Visual examination   

Please do the following inspection for all packing box   

Check  whether  the  packaging  is  intact  outside  the  equipment,  there  are 

situations, such as damage, soaks, out of shape, etc..   

Have  above-mentioned  situation  please  report  immediately  to  Zolix.  Or 

Representatives 

 

  (2) 

Unpacking procedures

 

Please open the packing box and make sure Do-Not uses the heavy-duty tool 

or opens rudely. With the proper tool according to the direction shown on the 

packing box so as not to cause inside equipment to be damaged. 

 

  (3) 

After unpacks

 

Please check equipment have appearance damage or corrosion, etc..   

Содержание GLORIA-X500A

Страница 1: ...GLORIA X500A 500W Xenon Light Source System Operation Manual Version 1 0 2015 4 Zolix Instruments Co Ltd...

Страница 2: ...ing 3 3 1 Light path 3 3 2 Xenon lamp bulb installation method 4 3 3 Light source housing operation guide and safety precautions 6 3 3 1 Adjustment before the xenon lamp is lighted 6 3 3 2 Adjustment...

Страница 3: ...ency and high pressure The high voltage short arc spherical xenon lamp can output the point light source and strong and stable continuous spectrum from UV to NIR The visible light is approximate to th...

Страница 4: ...MAX power 500W Parallel light spot dia 44mm theoretical value is 50mm from exit Divergence half angle 1 54 Spectrum range 200 2500nm 250 1800nm Lamp adjustment 2D Reflector adjustment 3D Xenon lamp l...

Страница 5: ...ix com cn 3 Xenon lamp light source housing 3 1 Light path In the xenon lamp housing the output light energy is enhanced by spheric reflect mirror behind the xenon lamp Collimating lens collects the l...

Страница 6: ...w zolix com cn E mail info zolix com cn 3 2 Xenon lamp bulb installation method Caution You must make sure the power supply is turned off when you mounting the xenon lamp Side plate Remove the side pl...

Страница 7: ...he light source housing 3 Before installation you d better swab the lamp with alcohol for fear that the transmittance and life time will not be detracted by the sweat on hand oil pollution or dusty co...

Страница 8: ...n lamp is lighted 1 Adjust 3 reflector turret at the same time make the diatance between light cup underside and adjusting bracket base is about 3mm 2 Reove collimating lens barrel then adjust shift k...

Страница 9: ...the vertical adjusting knob which can make the lamp bulb self emission light spot moves up and down relative to the center of light tube solid line spot as shown above figure 2 make the light bulb gl...

Страница 10: ...radiation which can cause permanent damage to unprotected skin and eyes Therefore never look directly into the output beam any diffuse reflection or any specular mirror reflection even for a short pe...

Страница 11: ...ition 25A 20V Current accuracy 0 1 Power regulation rate 0 05 Load regulation rate 0 05 Ripple Current 10mA Voltage 20mVp p 4 2 Function Introductions The function of front panel and rear panel of HPS...

Страница 12: ...the knob and setting button the current value is displayed on the current display table Front output interface if the light source is connected to the front panel interface the 1 and 2 pin interfaces...

Страница 13: ...that the user can set the output current size at this time Cur When the setting actual current switching is up the Cur light is on indicating that the current meter shows the output current of the us...

Страница 14: ...e BNC port of the rear panel After the panel is connected with the high level BNC 5V light source start front panel switches lit the rear panel BNC is low 0V the light source is shut off the front pan...

Страница 15: ...be used to connect the light source and the main switch is closed The front panel displays the voltage current value and the working status indicator 2 Press the current inside outside the selection...

Страница 16: ...ructions for products Warning The interior part of the light source contains very intense ultraviolet light It can cause serious damage to the eyes and skin Never look directly into the output beam Xe...

Страница 17: ...e responsible for repairing or replacing the same type of product If artificial operative errors or unauthorized use or unauthorized access to repair or natural disasters and other irresistible factor...

Страница 18: ...her cannot be provided the product label serial number is the warranty start month note If the manufacturing month is January 2002 the warranty period to the end of January 2003 3 Warranty service obj...

Страница 19: ...diator cap 2 LSH500A 043 Anode Gland Nut 3 LSH500A 048 STRAP made in china 1 4 LBA XBO500HOFR OSRAM XBO500WHOFR Lamp bulb installion attachment 1 LSH500A 041 OSRAM radiator cap 2 LSH500A 044 Anode ply...

Отзывы: