manualshive.com logo in svg
background image

CV-TYQ_1617_E_20180329

16

17

4

If mineral or Alkalized Ionic water is 

used, calcium tends to build up on 

the surface of the Inner Container. If 

scale accumulates on the Inner 

Container or the Filter, boiling may 

become louder than usual and water 

may not dispense smoothly. 

Frequent cleaning is recommended 

when using mineral or Alkalized Ionic 

water.

To cancel the Citric Acid Cleaning at any time, 

unplug the Power Plug for more than 5 seconds.

Repeated citric acid cleaning may 

be necessary for hard-to-remove 

residues or if water does not 

dispense smoothly.

NOTE

Take precaution with the hot water 

and steam. You may scald yourself.

Take precaution as hot water may 

drip from the Spout, causing scalds.

When disposing hot water:

3

P.16

P.2

P.8

P.7

P.9

Is it okay to use the product for 

heating liquids other than water?

Do not fill the product with any liquid other than water. It may cause 

malfunction, or may overflow and cause scalding.

Is it okay to use mineral 

water or Alkalized Ionic 

water?

Yes. However, when mineral or Alkalized Ionic water is used, a floating 

residue may develop or milky white substance may form on the surface of the 

Inner Container. This is due to the ingredients in the water and is harmless to 

your health. Frequent cleaning is recommended.

I accidentally drank water while 

performing the Citric Acid Cleaning. 

Is this harmful to my health?

Please follow the instructions shown on the package of the citric acid 

cleaner CD-K03E-JU.

Is it okay to go out while 

the product is turned on?

It is safe to use the product unattended as it has an Automatic Shut-Off function (power 

to the heater will be automatically turned off), which will be activated once it is empty of 

water. However be careful not to repeat the boiling process without filling the Inner 

Container with water, as the Nonstick Coating may discolor and peel.

Does the water need to be 

changed every day?

To prevent scale from building up, please change the water at least once a 

day.

Check that the Filter is attached 

to the Inner Container.

Preparation:

If the Filter is dirty, remove 

it from the Inner Container, 

wash with a soft brush and 

reinstall.

NOTE

2

Beeps when the cleaning process is completed.

Turns on

5 long beeps

Cleaning times may vary 

depending on the amount 

of water, water 

temperature and room 

temperature.

Approx. 1.5 hours.

Cleaning time:

1

Beep

Beeps when the cleaning process begins.

In order to prevent gas bubbles and bubbling-over, the Citric Acid Cleaner for 

Electric Water Boilers (CD-K03E-JU) is recommended for cleaning. To 

purchase this cleaner, please visit an authorized Zojirushi dealer.

NOTE

Blinks

2 lights will 

blink.

LCD display will 

show a square as 

illustrated.

The square 

shown on the 

Display rotates.

2 lights will stop 

blinking and stay 

on.

Unplug the Power Plug, detach the 

Upper Lid and dispose water where 

indicated "EMPTY FROM HERE."

(Please take precautions not to splash water 

on the Hinge.)

To rinse, fill the Inner Container with 

water. Boil and dispense about a cup of 

hot water to rinse out the Spout, allow to 

cool, then dispose the remaining water.

Q&A ON PRODUCT USE

Please check the following 

points before calling for service.

TROUBLESHOOTING GUIDE

Condition

Cause

Remedy

The product has not been used for a long 

time.

Hot water has a 

disagreeable odor.

A mild plastic odor may be 

noticeable with a new product. 

This odor will gradually fade 

away.

You may smell chlorine (used 

for sterilization of tap water) 

after boiling.

Boil water, unlock and dispense 

about 1 liter of hot water. Discard 

the remaining. (see pg.7)

If this is an issue, use the regular Boil 

mode instead. (see pg.12) 

The regular Boil mode purges chlorine 

in tap water by boiling completion.

Scale or other residue has accumulated 

on the Inner Container.
You have not performed citric acid 

cleaning regularly.

Perform citric acid cleaning. 

(see pg.16)

If tap water is used under Quick Temp 

Function, it will take an additional 15 

minutes after heating completes at the set 

temperature removing up to 80% of the 

chlorine.

Do not drink 

the water used 

for citric acid 

cleaning.

HOW TO PERFORM CITRIC ACID CLEANING

Put 1 package of the Citric Acid Cleaner 

CD-K03E-JU in a cup and add warm water to 

dissolve. Pour it into the Inner Container and 

fill with water to the Maximum Water Level Line.

Do not fill over the 

Maximum Water Level 

Line. (Hot water may spill 

out, resulting in scalds.)

NOTE

Close the Upper Lid, insert the Power Plug and press the           button for 

more than 3 seconds.

625702-00

BF297053G-00

CD-K03E-JU

REPLACEMENT PARTS

Replacement parts may be available for an 

additional charge. Please replace damaged parts 

only with new parts.

When replacing parts, please record the model 

number and part name beforehand. Then contact 

the retail store where you purchased this product.

Parts Names

Parts Number

Citric Acid Cleaner for Electric 

Water Boilers (30g

×

4 packets)

Inner Lid Gasket

Filter

Perform every 1-3 month(s) of usage

Water does not heat up.

Connect the Power Plug.

Power Plug is not connected to an 

electrical outlet.

Содержание CV-TYQ40

Страница 1: ...the plug or adaptor or at the distribution board Caution Power Plug Fuse Cover Fuse 13A Fuse Cover Always follow basic safety precautions when using electrical appliances Read all instructions careful...

Страница 2: ...se burns or product failures Close the Upper Lid securely Hot water may spill out when the product is overturned resulting in scalds Do not use the product near walls or furniture Steam or heat may da...

Страница 3: ...rm temperature see pg 10 11 LCD display shows the water temperature and Timer settings NOTE Illustration is for reference only Actual display will not show all functions simultaneously during use QUIC...

Страница 4: ...Close the Upper Lid and connect the Power Cord 1 BOIL MODE Open the Upper Lid and fill the Inner Container with water using a pitcher or other ontainer Do not fill the Inner Container directly from a...

Страница 5: ...short circuit or electric shock Do not dispose hot water with the Upper Lid in place The Upper Lid may come off spilling hot water and causing scalds Do not allow water to splash on the Control Panel...

Страница 6: ...e and amount of water At a room temperature of 23 C Be sure to check that the KEEP WARM light is on and NOT blinking before dispensing Do not use the Quick Temp mode see pg 12 70 C is ideal for prepar...

Страница 7: ...80 C Keep Warm mode 6H 7H 8H 9H 10H Cancel temperature display Energy Saving mode Energy Saving mode Energy Saving Timer function Energy Saving Timer function 6H 7H 8H 9H 10H Energy Saving Timer func...

Страница 8: ...herwise becomes worn out Please purchase and replace with a new one Wipe with a soft wet sponge Inner Lid Wipe clean with a dry cloth Power Cord Filter Remove the Filter from the Inner Container and w...

Страница 9: ...revent gas bubbles and bubbling over the Citric Acid Cleaner for Electric Water Boilers CD K03E JU is recommended for cleaning To purchase this cleaner please visit an authorized Zojirushi dealer NOTE...

Страница 10: ...on Cause Remedy Condition Cause Remedy The Quick Temp mode is selected Water does not reach a boil under Quick Temp mode Press the REBOIL QUICK TEMP button select the regular Boil mode see P 12 Water...

Отзывы: