manualshive.com logo in svg
background image

CV-TYQ_0405_E_20180314

4

5

About 45 

degrees

Push

Lid Lock

Indented Area of 

the Lid Lock

Water Level Ball

REFILL Line

1

2

3

1

2

Upper Lid 

Detach button

A rattling sound you may 

hear when opening or 

closing the Upper Lid or 

when boiling is normal.

(see P.19)

This button must be pressed to 

dispense hot water. (see pg.8) 

Press this button again for Café 

Drip Function. 

(see pg.14) 

CONTROL PANEL

To Open

To Close

To Detach

PARTS NAMES AND FUNCTIONS

How to Open/Close the Upper Lid

How to Detach/Attach the Upper Lid

Press the indented area of the 

Lid Lock with your thumb.

Depress the Upper Lid until it 

clicks shut.

Pull the Lid Lock up with your 

fingers to open the Upper Lid.

Open the Upper Lid to about 

a 45-degree angle.

Push the Upper Lid Detach 

button.

Pull the Upper Lid forward 

and up at an angle.

1

2

1

2

3

To Attach

Push the Upper Lid back into 

place at the same angle.

Lid Lock

Steam Vent

Exercise care during the boiling 

process as steam emitting from 

the Steam Vent is very hot.

Inner Lid

If the Inner Lid Gasket hardens, changes 

shape, turns white, or otherwise 

becomes worn out, please replace it with 

a new one. (Separate charge required.) 

(see pg.16)

Not doing so may cause hot water to 

leak when the product is tilted or tipped 

over, resulting in scalding. Steam leaking 

from the gap may also cause burns or 

product failures.

Inner Lid Gasket

(Consumable Part)

Upper Lid

Press to dispense hot water. (see pg.8, 14)

Sets the Keep Warm temperature. 

(see pg.10-11)

LCD display shows the water 

temperature and Timer settings.

NOTE: Illustration is for reference only. Actual display will not 

show all functions simultaneously during use.

QUICK TEMP light
BOIL light

TEMP SET button

KEEP WARM light

Display

DISPENSE button

UNLOCK light

CAFÉ DRIP light

Power Cord

Cord

Swivel Base

Water Removal Area

Inner Container

Handle

Control Panel

Drain water here.

Appliance Plug 

inserts here.

Do not let the Power Cord wrap 

around the Main Body when turning.

Hot water dispenses from here.

For care and use instructions, 

see pg.15.

Filter

Maximum Water 

Level Line

Hinge

Receptacle

Water Level Gauge

Spout

Fill water above the line.

REFILL Line

Body

Twist Tie

Please remove the twist tie holding the 

Power Cord before use.

Do not use the Power Cord bundled up. 

Doing so may cause the Power Cord to 

become excessively hot, resulting in 

malfunction.

Appliance Plug

Press buttons down firmly.

The Sound Signals and raised dot ( 

 ) in the center of the 

DISPENSE button is provided for those with visual impairment.

Power Plug

REBOIL/

QUICK TEMP 

button

UNLOCK button

Starts the Reboil 

mode. (see pg.9)

Sets the Quick Temp 

mode. (see pg.12)

Use to return to the original 

temperature setting when 

Energy-Saving mode is 

selected. (see P.14)

Also used when performing the 

Citric Acid Cleaning (to initiate 

cleaning, press this button for more 

than 3 seconds). (see pg.16)

ENERGY-SAVING/

TIMER button

Use when setting the 

Energy-Saving mode or 

Energy-Saving Timer function. 

(see P.12-13) 

The Water Level Ball is not 

seen when the water level is 

higher than the scale of 

Water Level Gauge.

Water Level Ball

 (Red Ball)

Содержание CV-TYQ40

Страница 1: ...the plug or adaptor or at the distribution board Caution Power Plug Fuse Cover Fuse 13A Fuse Cover Always follow basic safety precautions when using electrical appliances Read all instructions careful...

Страница 2: ...se burns or product failures Close the Upper Lid securely Hot water may spill out when the product is overturned resulting in scalds Do not use the product near walls or furniture Steam or heat may da...

Страница 3: ...rm temperature see pg 10 11 LCD display shows the water temperature and Timer settings NOTE Illustration is for reference only Actual display will not show all functions simultaneously during use QUIC...

Страница 4: ...Close the Upper Lid and connect the Power Cord 1 BOIL MODE Open the Upper Lid and fill the Inner Container with water using a pitcher or other ontainer Do not fill the Inner Container directly from a...

Страница 5: ...short circuit or electric shock Do not dispose hot water with the Upper Lid in place The Upper Lid may come off spilling hot water and causing scalds Do not allow water to splash on the Control Panel...

Страница 6: ...e and amount of water At a room temperature of 23 C Be sure to check that the KEEP WARM light is on and NOT blinking before dispensing Do not use the Quick Temp mode see pg 12 70 C is ideal for prepar...

Страница 7: ...80 C Keep Warm mode 6H 7H 8H 9H 10H Cancel temperature display Energy Saving mode Energy Saving mode Energy Saving Timer function Energy Saving Timer function 6H 7H 8H 9H 10H Energy Saving Timer func...

Страница 8: ...herwise becomes worn out Please purchase and replace with a new one Wipe with a soft wet sponge Inner Lid Wipe clean with a dry cloth Power Cord Filter Remove the Filter from the Inner Container and w...

Страница 9: ...revent gas bubbles and bubbling over the Citric Acid Cleaner for Electric Water Boilers CD K03E JU is recommended for cleaning To purchase this cleaner please visit an authorized Zojirushi dealer NOTE...

Страница 10: ...on Cause Remedy Condition Cause Remedy The Quick Temp mode is selected Water does not reach a boil under Quick Temp mode Press the REBOIL QUICK TEMP button select the regular Boil mode see P 12 Water...