Appendix 1 20X Bar-tacking and Button Sewing Machine(LCD N)
85
Code
Name
Content
Solution
E-068
Stepping Close
Loop DSP2 2
nd
Route (X21)
Position Error
The detected encoder response
position is not consistent with the
position set in the order.
Change the stepping motor to open loop mode and run it. If
the motor can work normally, the motor is ok. If the motor
can’t work normally, user should check the driving part on
the stepping board and the motor itself. After the above
operations, user should check the encoder. Make sure the
connection and the condition of the encoder cable is ok.
And make sure the signal response part on the stepping
board and the encoder itself is ok.
E-069
Stepping Close
Loop DSP2 2
nd
Route (X21)
Over-speed
The system will give this warning
when it detects the abnormal motor
speed via the encoder response signal.
The checking method is the same with that for Position
Error
E-070
Stepping Board
90V Power Supply
Error
Stepping board 90V is over-current
Turn off the power supply and then turn it on again after a
while.
6.2 Operation Panel Error List
Code
Name
Content
Solution
M-300
Memory Abnormal
There exists error with the data
defined by the operation panel.
Internal error: user need update the panel program.
M-301
Memory Abnormal
Panel memory data abnormal
Internal error: user need update the panel program.
M-302
Machine Type
Parameter Error
The machine type data read by the
operation panel is not within the set
range.
Press RESET key to automatically enter parameter No.
241 to select and save the defined machine type.
M-303
UK Parameter
Abnormal
Abnormal range of the parameter read
by the panel from EEPROM
Press RESET key to enter the system menu and recover
the default setting.
M-304
Head Board
Parameter
Abnormal
Abnormal range of parameters
received by panel from down
computer
Press RESET key to enter the system menu and recover
the default setting.
M-305
Normal Pattern
Parameter
Abnormal
When using pattern parameter, the
panel detects abnormal parameter
range.
Press RESET key to enter the system menu and recover
the default setting.
M-306
Pattern Not Found
or Locked
The prepared pattern No. hasn’t been
registered to ROM or set as not to be
read. The pattern No. is displayed as
0.
Press RESET key, confirm the pattern No. and make sure
the pattern is unlocked.
M-307
Pattern Data
Abnormal
When the panel reads the sewing data
of the pattern, the data format is found
to be abnormal.
Select other patterns.
M-308
Sewing Data Too
Large
When being computed, the size of the
pattern data is found to be too large
Select other patterns for sewing.
Содержание 20X
Страница 1: ...20X 套结钉扣机 液晶按键 N Bar tacking and Button Sewing Machine LCD N ...
Страница 54: ...20X 套结钉扣机 液晶按键 N 附录 2 42 7 附录 2 7 1 电控箱安装尺寸 ...
Страница 55: ...附录 2 20X 套结钉扣机 液晶按键 N 43 7 2 操作箱安装尺寸 操作头 USB 接口 ...
Страница 56: ...20X 套结钉扣机 液晶按键 N 附录 2 44 7 3 系统框图 1 TASC201 2N B 系统框图 ...
Страница 102: ...20X Bar tacking and Button Sewing Machine LCD N Appendix 2 90 7 Appendix 2 7 1 Installation Size of Control Box ...
Страница 103: ...Appendix 2 20X Bar tacking and Button Sewing Machine LCD N 91 7 2 Installation Size of Operation Panel Panel USB Port ...
Страница 104: ...20X Bar tacking and Button Sewing Machine LCD N Appendix 2 92 7 3 The Control System Diagram 1 TASC201 2N B ...