Appendix 1 20X Bar-tacking and Button Sewing Machine(LCD N)
81
6
Appendix 1
6.1 Main Control Error List
Code
Name
Content
Solution
E-001
Pedal not in the
middle position
Pedal is stepped down when entering
the ready sewing status
Make sure the pedal is not stepped down when entering the
ready sewing status
E-002
Pause
RESET key is pressed while sewing
machine is running. The machine
pauses.
Restart or return-to-origin after pressing RESET key for
thread-trimming.
E-003
Head Tilt Error
Head tilt detection switch is set as
ON.
The sewing machine cannot be operated with the head
tilted. Return the sewing machine head to its proper
position.
E-004
Low Voltage Error
The voltage of power is too low.
Sampling UZKIN analog quantity is too low. Confirm the
voltage of power and related circuit.
E-005
Overvoltage Error
The voltage of power is over the
specified value.
The detected signal of AC_OVDT is high. Confirm the
voltage of power and related circuit.
E-007
Main shaft driver
abnormal
The error is detected in main shaft
driver.
Turn off the power and repower the machine after a while.
E-008
24V power supply
error
24V over-current
Turn off the power supply and then turn it on again after a
while.
E-009
24V power supply
error
24V voltage is too low
Turn off the power supply and then turn it on again after a
while.
E-010
Air valve (fan)
problem
After start, the system detects
abnormal signal about the voltage of
the air valve or fan.
Shut down the machine to check if there is any short circuit
E-012
Presser Foot
Position Error
Presser foot is not at proper position.
Turn off the power and check connection of the CZ025 at
the head signal circuit board. If the connection is ok, check
the optocoupler.
E-013
Encoder
Disconnection
The system can’t detect ADTC signal.
Turn off the power, and confirm whether plug X5 is
connected properly.
E-014
Motor Running
Abnormal
When the main shaft motor is
running, the range of the electrical
angle is abnormal at 0°
Shut down the machine to check the motor encoder.
E-015
Beyond Sewing
Area
The sewing area is beyond the limit.
Press RESET switch to confirm the pattern and its X/Y
scale rate.
Triggering condition: pattern computation error.
Содержание 20X
Страница 1: ...20X 套结钉扣机 液晶按键 N Bar tacking and Button Sewing Machine LCD N ...
Страница 54: ...20X 套结钉扣机 液晶按键 N 附录 2 42 7 附录 2 7 1 电控箱安装尺寸 ...
Страница 55: ...附录 2 20X 套结钉扣机 液晶按键 N 43 7 2 操作箱安装尺寸 操作头 USB 接口 ...
Страница 56: ...20X 套结钉扣机 液晶按键 N 附录 2 44 7 3 系统框图 1 TASC201 2N B 系统框图 ...
Страница 102: ...20X Bar tacking and Button Sewing Machine LCD N Appendix 2 90 7 Appendix 2 7 1 Installation Size of Control Box ...
Страница 103: ...Appendix 2 20X Bar tacking and Button Sewing Machine LCD N 91 7 2 Installation Size of Operation Panel Panel USB Port ...
Страница 104: ...20X Bar tacking and Button Sewing Machine LCD N Appendix 2 92 7 3 The Control System Diagram 1 TASC201 2N B ...