20X Bar-tacking and Button Sewing Machine(LCD N) Appendix 1
84
Code
Name
Content
Solution
E-061
Stepping Close
Loop DSP1 2
nd
Route (X25)
Position Error
The detected encoder response
position is not consistent with the
position set in the order.
Change the stepping motor to open loop mode and run it. If
the motor can work normally, the motor is ok. If the motor
can’t work normally, user should check the driving part on
the stepping board and the motor itself. After the above
operations, user should check the encoder. Make sure the
connection and the condition of the encoder cable is ok.
And make sure the signal response part on the stepping
board and the encoder itself is ok.
E-062
Stepping Close
Loop DSP1 2
nd
Route (X25)
Over- speed
The system will give this warning
when it detects the abnormal motor
speed via the encoder response signal.
The checking method is the same with that for Position
Error
E-063
Stepping Close
Loop
DSP2(X21/X23)
Communication
Error
The verification of the received order
at stepping board is failed
Check the connection of SPI communication cable
E-064
Stepping Close
Loop DSP2 1
st
Route (X23)
Over-Current
Large current is detected by hardware
At first, please check motor. Then check the resistance and
sensor value. If the motor is ok, user should check the
hardware on stepping board
E-065
Stepping Close
Loop DSP2 1
st
Route (X23)
Position Error
The detected encoder response
position is not consistent with the
position set in the order.
Change the stepping motor to open loop mode and run it. If
the motor can work normally, the motor is ok. If the motor
can’t work normally, user should check the driving part on
the stepping board and the motor itself. After the above
operations, user should check the encoder. Make sure the
connection and the condition of the encoder cable is ok.
And make sure the signal response part on the stepping
board and the encoder itself is ok.
E-066
Stepping Close
Loop DSP2 1
st
Route (X23)
Over- speed
The system will give this warning
when it detects the abnormal motor
speed via the encoder response signal.
The checking method is the same with that for Position
Error
E-067
Stepping Close
Loop DSP2 2
nd
Route
(X21)Over-current
Large current is detected by hardware
At first, please check motor. Then check the resistance and
sensor value. If the motor is ok, user should check the
hardware on stepping board
Содержание 20X
Страница 1: ...20X 套结钉扣机 液晶按键 N Bar tacking and Button Sewing Machine LCD N ...
Страница 54: ...20X 套结钉扣机 液晶按键 N 附录 2 42 7 附录 2 7 1 电控箱安装尺寸 ...
Страница 55: ...附录 2 20X 套结钉扣机 液晶按键 N 43 7 2 操作箱安装尺寸 操作头 USB 接口 ...
Страница 56: ...20X 套结钉扣机 液晶按键 N 附录 2 44 7 3 系统框图 1 TASC201 2N B 系统框图 ...
Страница 102: ...20X Bar tacking and Button Sewing Machine LCD N Appendix 2 90 7 Appendix 2 7 1 Installation Size of Control Box ...
Страница 103: ...Appendix 2 20X Bar tacking and Button Sewing Machine LCD N 91 7 2 Installation Size of Operation Panel Panel USB Port ...
Страница 104: ...20X Bar tacking and Button Sewing Machine LCD N Appendix 2 92 7 3 The Control System Diagram 1 TASC201 2N B ...