10
2
、
Panel Pause
After user set the value of No.31 parameter at 1,
or the reverse gear of pedal can be used as
the pause key.
1
)
If user presses
or depresses the reverse gear of pedal, the sewing machine will stop and
display the error No.50.
2
)
The following are the three available operations after the pause:
①
Press the Start Switch to start the sewing.
②
Press
and perform the thread-trimming. After that, use
&
to adjust the
position and then press start switch to start sewing.
③
Press
and trim the thread. After that, press
again to return to the origin.
2.3 Set P Pattern & C Pattern
2.3.1 Use Pattern Key
(
)
for Sewing
The saved patterns (No.1~200) can be registered on P1~P50. It is possible to change and
register the scale rate, Max speed limitation and sewing position. With the rolling window of
pattern, user can also register patterns and has access to the pattern from P1~P25 at a time.
·For selecting P6~P25, user can use the combinations of
(simultaneous pressing) shown in the below table at his sewing.
P-No.
Selection Key
P-No.
Selection Key
P-No.
Selection Key
P-No.
Selection Key
P1 P1
P8
P1+P4
P15 P4
+P5
P22
P2+P3+P4
P2 P2
P9
P1+P5
P16 P1+P2+P3
P23
P2+P3+P5
P3 P3
P10 P2+P3
P17 P1+P2+P4
P24
P2+P4+P5
P4 P4
P11 P2+P4
P18 P1+P2+P5
P25
P3+P4+P5
P5 P5
P12 P2+P5
P19 P1+P3+P4
P6 P1+P2
P13 P3+P4
P20 P1+P3+P5
P7 P1+P3
P14 P3+P5
P21 P1+P4+P5
1
.
Registration on Pattern Key
Exp
:
Register pattern No.3 to P2, X scale rate: 50%; Y scale rate: 80%; Max speed limitation:
2000 rpm, pattern position: 0.5mm to the right and 1mm to the front.
1
)
Turn on the power, press
(the sewing
LED shall be off at this moment) to have
access to Mode Setting (Setting of Storage
Switch).