background image

2

© Copyright 2022 Zoeller

®

 Co. All rights reserved.

The DC controller is equipped with a charger for maintaining the battery 
in a ready state and recharging the battery after use when AC power is 
restored. Time for recharge depends upon the amount of power consumed 
by the pumping cycle during the AC power interruption. The pump may go 
back to the ready run position in a very short period of time. A completely 

drained battery may require up to 24 hours for full recharge. If battery does 

not charge properly, the battery LED will flash red. 

LIMITED WARRANTY

PERFORMANCE

The DC pump performance at 12.7 Vdc

BATTERY SELECTION

Manufacturer warrants, to the purchaser and subsequent owner during the 

warranty period, every new product to be free from defects in material and 

workmanship under normal use and service, when properly used and maintained, 

for a period of 3 years (models 508/53 and 508/98)  or 5 years (508/63) from date 

of purchase by the end user. Zoeller batteries have a 3 year warranty. Proof of 

purchase is required. Parts that fail within the warranty period, that inspections 

determine to be defective in material or workmanship, will be repaired, replaced or 

remanufactured at Manufacturer's option, provided however, that by so doing we 

will not be obligated to replace an entire assembly, the entire mechanism or the 

complete unit. No allowance will be made for shipping charges, damages, labor 

or other charges that may occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable 

act of nature; that has not been installed, operated or maintained in accordance 

with Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following:  sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or feminine sanitary products, 

etc. in all pumping applications. The warranty set out in the paragraph above is 

in lieu of all other warranties expressed or implied; and we do not authorize any 

representative or other person to assume for us any other liability in connection 

with our products.

Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, Attention: 

Customer Support Department to obtain any needed repair or replacement of 

part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL 

OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; 

AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND 

OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED 

WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so 

the above limitation may not apply to you. Some states do not allow the exclusion 

or limitation of incidental or consequential damages, so the above limitation or 

exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

Discharge

Feet of Head

5

(1.5 m)

10

(3 m)

15

(4.6 m)

28

(85 m)

Flow

GPM (LPM)12.7 volts

43

(163)

35

(132)

27

(102)

Shut-off

Head

This system is a combination of a primary sump pump and a backup pump to your primary sump pump. It is designed to protect against flooding during power 

outages or primary pump failure. This system is unique in that it has self-testing and communication features when connected to the Z Control Cloud. The pump 

is self-priming and specifically designed and manufactured by Zoeller as a purpose-built DC sump pump, rather than a repurposed bilge pump. The controller 

has smart diagnostics built in. If the DC pump is unplugged or jammed, for example, a fault alarm will result. If either float switch is missing/unplugged, it will 

create an immediate alarm condition. The controller will recognize the difference between a pump that is pumping air vs. a pump that is pumping water. This 

will lead to behaviors designed to purge air and remedy an air lock situation. The controller also has smart float logic that is designed to prevent a continuous 

running pump (or run dry pump condition). Zoeller uses a normally open operational float switch, and a normally closed high water float switch. The advanced 

technology hardware and firmware in the Fit controller will recognize, attempt to remedy, and alarm for many conditions that have not previously been possible. 

The controller will automatically charge and maintain the battery in a way designed to extend battery life.

DESCRIPTION

The DC emergency pump system requires a good quality, 12 volt battery 
to obtain maximum pumping time during a power outage. A deep-cycle, 12 
volt, 90 amp-hour or larger marine battery is recommended. A 100+ amp 

hour battery will provide approximately 5.5 hours or more of continuous 
pumping time in a sump pump installation with 8' (2.4 m) of head pressure. 
In most installations, the pump runs intermittently and the battery life is 
extended accordingly. Batteries with top terminals are recommended for 
ease of installation. "Wet" cell batteries contain acid, and proper precaution 
must be taken when handling. Battery box will accommodate a maximum 
battery size of 13-1/2" (34.3 cm) Length x 7" (17.8 cm) Width x 9-1/2" (24.1 

cm) Height. AGM batteries also recommended. Do not use gel batteries 

or automotive batteries.

Primary 

Pump

Construction

Cast iron & plastic, premium seals

Performance

53: 34 GPM       98: 61 GPM

63: 34 GPM      measured @ 10' head

DC Pump

Construction

Non-corrodible plastic, premium seals

Performance

35 GPM at 10' (113 LPM at 3 m) at 12.7 volts

Continuous Running Time

5.5 hours with recommended battery

Duty Cycle of 10%

2 days

Connection

9' (2.7 m) cord with connector

Controller

Construction

ABS plastic

Power Requirement

115 V 15 amp circuit

Consumption

Up to 3 amps at 115 V

Charger output

7 amp multi-stage

Connections

8' (2.4 m) AC power cord, 6' (1.8 m) DC charging cable, connections for pump, operation switch, high water switch

Z Control

WiFi

Built in

Battery 

Box

Construction

Non-corrodible plastic

Safety

Snap tight lid, keeps battery safe and clean

  

* When AC power is available, the controller will replace the power used by the pump once the pump shuts off.  

 

   Even during moderate pump cycling, the system may be capable of running indefinitely.

In instances where property damages are incurred as a result of an alleged product failure, the property 

owner must retain possession of the product for investigation purpose.  

Содержание ProPak AQUANOT FIT 508/63

Страница 1: ...5 V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling cle...

Страница 2: ...state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a combination of a primary sump pump and a backup pump to your pr...

Страница 3: ...Install the Fit Controller see Figure 3 by using the anchors provided For best cooling install wall mount configuration The controller should be located at least 3 1 m above the sump 9 Connect the lea...

Страница 4: ...controllerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump...

Страница 5: ...DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HI WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SC...

Страница 6: ...oller 1 155368 9 Fuse 30 amp automotive blade type 1 016918 10 High water float N C 1 155653 11 Battery box asm box and cover 1 10 0764 12 Hardware pak charger switch mode 2 152864 13 Pump M53 115V 1...

Страница 7: ...ed Z Control Connected Searching Broadcasting SSID or Dormant Note will not persist if pump didn t pump water See also the laminated label affixed to the controller s cord This cord label also describ...

Страница 8: ...oints Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check f...

Страница 9: ...rol Cloud will also be updated with the firmware update information and notification to email accounts will occur 5 You now should go back to the Z Control app to find your new device set up in the lo...

Страница 10: ...ection to router is not successful If you need to force the Fit into AP mode again press the Z Control button for 12 seconds See Figure A This will cause the Fit to re enter AP mode and begin transmit...

Страница 11: ...ng installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofi...

Страница 12: ...s by products capable of causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year...

Отзывы: