2
© Copyright 2022 Zoeller
®
Co. All rights reserved.
The DC controller is equipped with a charger for maintaining the battery
in a ready state and recharging the battery after use when AC power is
restored. Time for recharge depends upon the amount of power consumed
by the pumping cycle during the AC power interruption. The pump may go
back to the ready run position in a very short period of time. A completely
drained battery may require up to 24 hours for full recharge. If battery does
not charge properly, the battery LED will flash red.
LIMITED WARRANTY
PERFORMANCE
The DC pump performance at 12.7 Vdc
BATTERY SELECTION
Manufacturer warrants, to the purchaser and subsequent owner during the
warranty period, every new product to be free from defects in material and
workmanship under normal use and service, when properly used and maintained,
for a period of 3 years (models 508/53 and 508/98) or 5 years (508/63) from date
of purchase by the end user. Zoeller batteries have a 3 year warranty. Proof of
purchase is required. Parts that fail within the warranty period, that inspections
determine to be defective in material or workmanship, will be repaired, replaced or
remanufactured at Manufacturer's option, provided however, that by so doing we
will not be obligated to replace an entire assembly, the entire mechanism or the
complete unit. No allowance will be made for shipping charges, damages, labor
or other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material
or product that has been disassembled without prior approval of Manufacturer,
subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable
act of nature; that has not been installed, operated or maintained in accordance
with Manufacturer's installation instructions; that has been exposed to outside
substances including but not limited to the following: sand, gravel, cement, mud,
tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other
abrasive or corrosive substances, wash towels or feminine sanitary products,
etc. in all pumping applications. The warranty set out in the paragraph above is
in lieu of all other warranties expressed or implied; and we do not authorize any
representative or other person to assume for us any other liability in connection
with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211, Attention:
Customer Support Department to obtain any needed repair or replacement of
part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL
OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY;
AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND
OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED
WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so
the above limitation may not apply to you. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights
which vary from state to state.
Discharge
Feet of Head
5
(1.5 m)
10
(3 m)
15
(4.6 m)
28
(85 m)
Flow
GPM (LPM)12.7 volts
43
(163)
35
(132)
27
(102)
Shut-off
Head
This system is a combination of a primary sump pump and a backup pump to your primary sump pump. It is designed to protect against flooding during power
outages or primary pump failure. This system is unique in that it has self-testing and communication features when connected to the Z Control Cloud. The pump
is self-priming and specifically designed and manufactured by Zoeller as a purpose-built DC sump pump, rather than a repurposed bilge pump. The controller
has smart diagnostics built in. If the DC pump is unplugged or jammed, for example, a fault alarm will result. If either float switch is missing/unplugged, it will
create an immediate alarm condition. The controller will recognize the difference between a pump that is pumping air vs. a pump that is pumping water. This
will lead to behaviors designed to purge air and remedy an air lock situation. The controller also has smart float logic that is designed to prevent a continuous
running pump (or run dry pump condition). Zoeller uses a normally open operational float switch, and a normally closed high water float switch. The advanced
technology hardware and firmware in the Fit controller will recognize, attempt to remedy, and alarm for many conditions that have not previously been possible.
The controller will automatically charge and maintain the battery in a way designed to extend battery life.
DESCRIPTION
The DC emergency pump system requires a good quality, 12 volt battery
to obtain maximum pumping time during a power outage. A deep-cycle, 12
volt, 90 amp-hour or larger marine battery is recommended. A 100+ amp
hour battery will provide approximately 5.5 hours or more of continuous
pumping time in a sump pump installation with 8' (2.4 m) of head pressure.
In most installations, the pump runs intermittently and the battery life is
extended accordingly. Batteries with top terminals are recommended for
ease of installation. "Wet" cell batteries contain acid, and proper precaution
must be taken when handling. Battery box will accommodate a maximum
battery size of 13-1/2" (34.3 cm) Length x 7" (17.8 cm) Width x 9-1/2" (24.1
cm) Height. AGM batteries also recommended. Do not use gel batteries
or automotive batteries.
Primary
Pump
Construction
Cast iron & plastic, premium seals
Performance
53: 34 GPM 98: 61 GPM
63: 34 GPM measured @ 10' head
DC Pump
Construction
Non-corrodible plastic, premium seals
Performance
35 GPM at 10' (113 LPM at 3 m) at 12.7 volts
Continuous Running Time
5.5 hours with recommended battery
Duty Cycle of 10%
2 days
Connection
9' (2.7 m) cord with connector
Controller
Construction
ABS plastic
Power Requirement
115 V 15 amp circuit
Consumption
Up to 3 amps at 115 V
Charger output
7 amp multi-stage
Connections
8' (2.4 m) AC power cord, 6' (1.8 m) DC charging cable, connections for pump, operation switch, high water switch
Z Control
WiFi
Built in
Battery
Box
Construction
Non-corrodible plastic
Safety
Snap tight lid, keeps battery safe and clean
* When AC power is available, the controller will replace the power used by the pump once the pump shuts off.
Even during moderate pump cycling, the system may be capable of running indefinitely.
In instances where property damages are incurred as a result of an alleged product failure, the property
owner must retain possession of the product for investigation purpose.