background image

12

© Copyright 2022 Zoeller

®

 Co. All rights reserved.

CARBON MONOXIDE DETECTORS

Some battery types used in battery backup systems, regardless of brand or manufacturer, have the potential to give off gaseous by-products when 

charging. Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. 

In order to help prevent false activation, Zoeller Pump Company recommends moving the battery as far away from the CO detector as possible or, 

if necessary, venting the battery to the exterior. Zoeller Pump Company provides the previous statements only as guidelines to help prevent false 

activation of the CO detector. In no way are these statements intended to supersede the instructions that accompany the detector, nor do they 

supersede advice from the CO detector manufacturer.
If the audible alarm associated with your CO detector is activated, we recommend the following actions:

1)  Take immediate action for personal safety as recommended in the CO detector literature.

2)  Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural 

gas.

3)  If you are certain that no CO is being produced, a charging battery may be producing gaseous by-products capable of causing the CO detector 

to activate. Contact the manufacturer and ask for recommendations to prevent the alarm activation.

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become 

fully charged and may damage the charging circuits of the controller. It is for this reason that Zoeller offers its own line of batteries. We offer 

maintenance-free, deep cycle batteries capable of running the pump continuoulsy for over 5.5 hours. These times are based on continuous 

pumping at 10' of static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery.

Follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger

•  Replace your battery every 3 years

•  Do not let corrosion build up on the battery terminals

•  To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)

•  Use of the included plastic battery box is recommended to keep the battery safe and clean. 

PROTECT YOUR WARRANTY:  

•  Water level in batteries must be checked once a month (wet cell batteries only)

•  Do not use gel batteries

THE AQUANOT

®

 

BATTERY

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • 

FAX

 (502) 774-3624

Visit our website:

zoellerpumps.com

These are the original installation instructions.

Содержание ProPak AQUANOT FIT 508/63

Страница 1: ...5 V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling cle...

Страница 2: ...state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a combination of a primary sump pump and a backup pump to your pr...

Страница 3: ...Install the Fit Controller see Figure 3 by using the anchors provided For best cooling install wall mount configuration The controller should be located at least 3 1 m above the sump 9 Connect the lea...

Страница 4: ...controllerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump...

Страница 5: ...DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HI WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SC...

Страница 6: ...oller 1 155368 9 Fuse 30 amp automotive blade type 1 016918 10 High water float N C 1 155653 11 Battery box asm box and cover 1 10 0764 12 Hardware pak charger switch mode 2 152864 13 Pump M53 115V 1...

Страница 7: ...ed Z Control Connected Searching Broadcasting SSID or Dormant Note will not persist if pump didn t pump water See also the laminated label affixed to the controller s cord This cord label also describ...

Страница 8: ...oints Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check f...

Страница 9: ...rol Cloud will also be updated with the firmware update information and notification to email accounts will occur 5 You now should go back to the Z Control app to find your new device set up in the lo...

Страница 10: ...ection to router is not successful If you need to force the Fit into AP mode again press the Z Control button for 12 seconds See Figure A This will cause the Fit to re enter AP mode and begin transmit...

Страница 11: ...ng installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofi...

Страница 12: ...s by products capable of causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year...

Отзывы: