9
© 2020. All rights reserved.
There are two buttons on the front of the controller.
1. Silence/Reset - Can be pressed to silence current
alarms for 24 hours.
Can be held for 3+ seconds to reset (or clear) alarms
and LEDs. Flashing LEDs for conditions such as bad/
disconnected battery or power outage, for example,
can’t be cleared by Silence/Reset. These conditions
must be resolved to eliminate the LED indicator.
BASEMENT SENTRY CONTROLLER FUNCTIONS
AC
POWER
FLOAT
STATUS
BATTERY
DC
PUMP
SILENCE
TEST
24/7 BASEMENT
PROTECTION
USB
RESET
FLOAT
DC
PUMP
FUSE
30 AMP
by
FW2065 A
P L U S
1-800-584-8089
BasementSentry.com
DC POWER
+ 15V DC 1.6A
Test
2
AC
POWER
FLOAT
STATUS
BATTERY
DC
PUMP
SILENCE
TEST
24/7 BASEMENT
PROTECTION
USB
RESET
FLOAT
DC
PUMP
FUSE
30 AMP
by
FW2065 A
P L U S
1-800-584-8089
BasementSentry.com
DC POWER
+ 15V DC 1.6A
Silence/
Reset
1
2. Test - Will run the pump to determine if amp draw of
pump is within range.
Controller is factory programmed to self-test the pump
for several seconds every 7 days. This schedule may
be modified once the controller is connected to the Z
Control Cloud.
Pressing the test button will start the 7 day timer for
self-testing.
Test and Silence/Reset -
Holding both buttons together for about six seconds
will initiate a factory reset. This returns the firmware’s
device configuration to the state in which it left the
factory. Any over-the-air firmware updates that have
been installed will be retained.
BASEMENT SENTRY LED LIGHT FUNCTIONS
AC
POWER
BATTERY
FLOAT
STATUS
DC
PUMP
AC
POWER
BATTERY
AC
POWER
BATTERY
FLOAT
STATUS
DC
PUMP
AC
POWER
BATTERY
Содержание Basement Sentry STBB200